• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Shear Bond Strength of Aged Composite Restorations Repaired with a Universal Injectable Composite

Tarih

2019

Yazar

Gonulol, Nihan
Almasifar, Lena
Cabadag, Ozge Gizem
Misilli, Tugba
Kalyoncuoglu, Elif

Üst veri

Tüm öğe kaydını göster

Özet

Objective: The purpose of this study was to analyze the shear bond strength of a universal injectable composite used in the repair of aged composites. Methods: A total of 100 disk-shaped specimens (8 mmx2 mm) were produced using five different composites (n=20) (Gradia Direct Posterior, Tetric N Ceram BulkFill, Filtek Z250, SonicFill and Filtek BulkFill Posterior). Specimens were polymerized using an LED light curing unit for 20 s and stored at 37 degrees C in distilled water for 3 weeks. Specimens were subdivided into two groups per composite for repair using either the same composite used for the specimen or G-aenial Universal Flo. Following acid-etching and silane application, a universal adhesive (G-Premio BOND) was applied and light-cured. The repair materials were placed on the bonded surfaces of the specimens and polymerized in silicone molds (2 mmx2 mm). After thermocycling to simulate aging, shear bond strength (SBS) was tested using a universal testing machine at a crosshead speed of 1 mm/min. Failure modes were examined using a stereomicroscope at x40 magnification. Results: No statistically significant differences were found among the tested composites repaired with their own substrates. However, the SBS SonicFill and Filtek Bulk Fill Posterior groups had significantly lower bond strengths when repaired with G-aenial Universal Flo in comparison to repairs made with their own substrates (p<0.05). Conclusion: When repaired with their own substrates, reliable bond strengths were obtained for all the composites tested.

Kaynak

European Journal of Therapeutics

Cilt

25

Sayı

4

Bağlantı

https://doi.org/10.5152/EurJTher.2019.18056
https://hdl.handle.net/20.500.12712/10448

Koleksiyonlar

  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.