Titanium Alloy Intramedullary Nails and Plates Affect Serum Metal Ion Levels within the Fracture Healing Period

Tarih

9999

Yazar

Tanoglu, Oguzhan
Say, Ferhat
Yucens, Mehmet
Alemdaroglu, Kadir Bahadir
Iltar, Serkan
Aydogan, Nevres Hurriyet

Üst veri

Tüm öğe kaydını göster

Özet

Titanium alloy implants are the most used materials for the fixation of lower extremity fractures. Although these implants were thought to be inert materials in vitro, several studies have shown increased serum and remote tissue metal ion levels due to wear of implants and friction of the bone-implant interface in vivo. The aim of this study was to investigate the alteration of serum metal ion levels that are released from intramedullary nails and plates used for the fixation of lower extremity fractures, within the fracture healing period. The study included 20 adult patients, who were treated with intramedullary nail or plate osteosynthesis due to closed lower extremity fractures. Alterations of serum titanium, aluminum, molybdenum, and vanadium levels were evaluated at 6, 12, 18, and 24 weeks postoperatively. A statistically significant increase was determined in serum titanium, aluminum, molybdenum, and vanadium ion levels in the intramedullary nail and plate groups at the end of the follow-up period. Pairwise comparisons of metal ion levels between implant groups revealed no significant difference during a 24-week follow-up period. Compared to the control group, statistically significant increased levels of serum titanium, aluminum, vanadium, and molybdenum ions were determined in the implant groups used for the fixation of lower extremity fractures at the end of 24 weeks. In the current literature, the potential toxic effects of prolonged exposure to low levels of these metal ions are still unknown. It can be predicted that long-term metal ion exposure could result in vivo pathological processes in the future.

Kaynak

Biological Trace Element Research

Bağlantı

https://doi.org/10.1007/s12011-019-01913-1
https://hdl.handle.net/20.500.12712/10543

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.