Basit öğe kaydını göster

dc.contributor.authorOzyurek, Taha
dc.contributor.authorUslu, Gulsah
dc.contributor.authorYilmaz, Koray
dc.contributor.authorGundogar, Mustafa
dc.date.accessioned2020-06-21T13:11:05Z
dc.date.available2020-06-21T13:11:05Z
dc.date.issued2018
dc.identifier.issn0099-2399
dc.identifier.issn1878-3554
dc.identifier.urihttps://doi.org/10.1016/j.joen.2018.03.004
dc.identifier.urihttps://hdl.handle.net/20.500.12712/11606
dc.descriptionozyurek, taha/0000-0003-3299-3361en_US
dc.descriptionWOS: 000434907000021en_US
dc.descriptionPubMed: 29680720en_US
dc.description.abstractIntroduction: The purpose of this article was to compare the cyclic fatigue resistance of Reciproc and Reciproc Blue files (VDW GmbH, Munich, Germany) that were used to prepare root canals of mandibular molar teeth with or without a glide path. Methods: Sixty Reciproc R25 and 60 Reciproc Blue R25 files were used. The Reciproc and Reciproc Blue groups were divided into 3 subgroups (ie, as received condition, used without a glide path, and used with a glide path). All the instruments were rotated in a stainless steel artificial canal with an inner diameter of 1.5 mm, a 60 angle of curvature, and a radius of curvature of 5 mm until fracture occurred. The number of cycle to fracture was calculated, and the length of the fractured segments was measured. The Kruskal-Wallis test was performed to statistically analyze the data using SPSS 21.0 software (IBM Corp, Armonk, NY) at a 5% significance level. Results: The cyclic fatigue resistance of as received condition Reciproc Blue files was found to be higher than as received condition Reciproc files (P < .05). Reciproc Blue files used for root canal preparation showed higher cyclic fatigue resistance than Reciproc files used for root canal preparation (P < .05). There was no statistically significant difference between Reciproc and Reciproc Blue files used with a glide path and without a glide path (P > .05). There was no statistically significant difference in the mean length of the fractured fragments of the instruments (P > .05). Conclusions: Within the limitations of this in vitro study, it was concluded that creating a glide path using ProGlider files had no effect on the cyclic fatigue resistance of RPC and RPC Blue files.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Incen_US
dc.relation.isversionof10.1016/j.joen.2018.03.004en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCyclic fatigueen_US
dc.subjectglide pathen_US
dc.subjectnickel-titaniumen_US
dc.subjectReciprocen_US
dc.subjectReciproc Blueen_US
dc.titleEffect of Glide Path Creating on Cyclic Fatigue Resistance of Reciproc and Reciproc Blue Nickel-titanium Files: A Laboratory Studyen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume44en_US
dc.identifier.issue6en_US
dc.identifier.startpage1033en_US
dc.identifier.endpage1037en_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster