dc.description.abstractIn this paper, the optimum insulation thicknesses, energy savings, payback periods and emission rates of CO2 were determined for poultry buildings in the cities of Antalya, Samsun, Ankara and Erzurum, located in different climates of Turkey. The calculations were made considering five different fuels (coal, fuel-oil, natural gas, LPG and electricity) and two different insulation materials, extruded polystyrene (XPS) and expanded polystyrene (EPS). As a result of this study, it was determined that XPS insulation materials offered an optimum thickness ranging from 1.20 to 8.10 cm, provided an energy savings between 15.38% and 69.90%, and required payback periods between 3.02 and 0.90 years, while EPS insulation materials offered an optimum thickness ranging between 2.00 and 11.80 cm, provided an energy savings between 21.82% and 70.61%, and required payback periods between 2.64 and 0.78 years, depending on the cities and fuel types. The lowest values of reduction of CO2 emission (39.82%) were obtained for Antalya when XPS and natural gas are used as optimum insulation material while Erzurum has the highest value (83.98%) for EPS and LPG. (C) 2018 Elsevier Ltd. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.isversionof10.1016/j.energy.2018.02.153en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectInsulationen_US
dc.subjectEnergy savingsen_US
dc.subjectClimate zonesen_US
dc.subjectDegree daysen_US
dc.subjectPoultryen_US
dc.titleA study on environmental impact of insulation thickness of poultry building wallsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume150en_US
dc.identifier.startpage583en_US
dc.identifier.endpage590en_US
dc.relation.journalEnergyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster