Show simple item record

dc.contributor.authorKurnaz, Cetin
dc.contributor.authorAygun, Tulay
dc.date.accessioned2020-06-21T13:12:02Z
dc.date.available2020-06-21T13:12:02Z
dc.date.issued2018
dc.identifier.isbn978-1-5386-7171-9
dc.identifier.urihttps://hdl.handle.net/20.500.12712/11808
dc.description26th Telecommunications Forum (TELFOR) -- NOV 20-21, 2018 -- Belgrade, SERBIAen_US
dc.descriptionWOS: 000459714200041en_US
dc.description.abstractIn this study, electrical field strength (E) level measurements were conducted in indoor and outdoor at seven hospitals in the city center of Samsun/Turkey. E measurements were made with Narda SRM-3006 electromagnetic field meter, which can measure the frequency band between 30 MHz and 3 GHz selectively. Measurements results show that the highest E value within the hospital is 0.818 V/m, while this value is 2.627 V/m for out of hospital. The E exposed outdoor of the hospital is 2.93 times higher than indoor of the hospital for measurement locations. The main sources of total E in the environments are base stations, and their contributions are 92.5% and 98.6% for indoor and outdoor of the hospital respectively. The most contribution of 53.4% total E is base stations using 2100 MHz frequency.en_US
dc.description.sponsorshipTelecommunicat Soc, Univ Belgrade, Sch Elect Engn, IEEE Serbia & Montenegro COM Chapter, Telekom Serbija a d, Minist Trade Tousim & Telecommunicat, VLATACOM d o o, ERICSSON, IRITEL a d BEOGRAD, MAKSNET Telekomunikacije, Minist Educ Sci & Technol Dev, MDS, Publ PTT Enterprise Srbija, Republ Agcy Elect Communicat Serbia, ROAMING Networks, TERI Engn, VIP Mobile, CISCO, IEEE Serbia & Montenegro Sect, KAPSCH, Serbian Natl Register of Internet Domain Names, IEEE Commun Soc Serbia & Montenegro Chapter, IEEE Reg 8, mtsen_US
dc.description.sponsorshipOndokuz Mayis University Research Fund, Graduate Thesis Support Program; [PYO.MUH.1904.17.017]en_US
dc.description.sponsorshipThe study is supported by Ondokuz Mayis University Research Fund, Graduate Thesis Support Program, and Project No: PYO.MUH.1904.17.017.en_US
dc.language.isoengen_US
dc.publisherIeeeen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBase stationen_US
dc.subjectElectromagnetic fielden_US
dc.subjectElectric field strength (E)en_US
dc.subjectBand selective E measurementsen_US
dc.subjectSRM-3006en_US
dc.titleCharacterization of Indoor and Outdoor Electric Field Strength Levels at Hospitalsen_US
dc.typeconferenceObjecten_US
dc.contributor.departmentOMÜen_US
dc.identifier.startpage164en_US
dc.identifier.endpage167en_US
dc.relation.journal2018 26Th Telecommunications Forum (Telfor)en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US