Basit öğe kaydını göster

dc.contributor.authorOzyurek, Taha
dc.contributor.authorYilmaz, Koray
dc.contributor.authorUslu, Gulsah
dc.date.accessioned2020-06-21T13:19:46Z
dc.date.available2020-06-21T13:19:46Z
dc.date.issued2017
dc.identifier.issn0099-2399
dc.identifier.issn1878-3554
dc.identifier.urihttps://doi.org/10.1016/j.joen.2016.12.010
dc.identifier.urihttps://hdl.handle.net/20.500.12712/12470
dc.descriptionozyurek, taha/0000-0003-3299-3361en_US
dc.descriptionWOS: 000400797800023en_US
dc.descriptionPubMed: 28292599en_US
dc.description.abstractIntroduction: The aim of the present study was to compare the shaping ability of Reciproc (RPC; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent AG, Altsthtten, Switzerland), and WaveOne GOLD (WOG; Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium (NiTi) files made of different NiTi alloys in S-shaped simulated canals. Methods: Sixty S-shaped canals in resin blocks were prepared to an apical size of 0.25 mm using RPC R25, WOG Primary, and HEDM One File (n = 20 canal/per group) systems. Composite images were made from the superimposition of pre- and postinstrumentation images. The amount of resin removed by each system was measured using a digital template and image analysis software in 22 different points. Canal aberrations were also recorded. Data were statistically analyzed using the Kruskal-Wallis and post hoc Dunn tests at the 5% level. Results: NiTi file fracture was not observed during shaping of the simulated canals although a danger zone formation in 1 sample and a ledge in 1 sample were observed in the RPC group. There was no statistically significant difference between the WOG and HEDM groups' apical, medial, and corona! regions (P >.05). However, it was determined that the RPC group removed a statistically significantly higher amount of resin from all the canal regions when compared with the WOG and HEDM groups (P <.05). Conclusions: Within the limitation of the present study, it was determined that all of the tested NiTi files caused various levels of resin removal. However, WOG and HEDM NiTi files were found to cause a lower level of resin removal than RPC NiTi files.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Incen_US
dc.relation.isversionof10.1016/j.joen.2016.12.010en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCanal irregularityen_US
dc.subjectcontrolled memoryen_US
dc.subjectendodonticsen_US
dc.subjectGOLD wireen_US
dc.subjectnickel-titaniumen_US
dc.subjectshaping abilityen_US
dc.titleShaping Ability of Reciproc, WaveOne GOLD, and HyFlex EDM Single-file Systems in Simulated S-shaped Canalsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume43en_US
dc.identifier.issue5en_US
dc.identifier.startpage805en_US
dc.identifier.endpage809en_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster