dc.contributor.author | Ozyurek, Taha | |
dc.contributor.author | Uslu, Gulsab | |
dc.contributor.author | Inan, Ugur | |
dc.date.accessioned | 2020-06-21T13:26:38Z | |
dc.date.available | 2020-06-21T13:26:38Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 0099-2399 | |
dc.identifier.issn | 1878-3554 | |
dc.identifier.uri | https://doi.org/10.1016/j.joen.2016.10.044 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12712/12579 | |
dc.description | ozyurek, taha/0000-0003-3299-3361 | en_US |
dc.description | WOS: 000395971900021 | en_US |
dc.description | PubMed: 28139286 | en_US |
dc.description.abstract | Introduction: The purpose of this study was to compare the cyclic fatigue resistance of used and new ProGlider (Dentsply Maillefer, Ballaigues, Switzerland) and PathFile (Dentsply Maillefer) rotary glide path files. Methods: Forty ProGlider and 40 PathFile #2 instruments were used in the present study. In group 1, 20 PathFile #2 files and, in group 2, 20 ProGlider files were used to prepare a total of 40 J-shaped transparent acrylic blocks. In group 3 (control group), 20 new Path File files and, in group 4 (control group), 20 new ProGlider files were included. Cyclic fatigue testing of instruments was performed in a stainless steel artificial canal with a 5-mm radius of curvature and a 60 angle of curvature. All 80 instruments were rotated until fracture, and the number of cycles to failure (NCF) was recorded. Data were analyzed using 1-way analysis of variance to determine any statistical difference; the significance was determined at the 95% confidence level. Results: The used glide path files' NCF was lower than the new ones; however, this difference was not statistically significant (P > .05). The cyclic fatigue resistance of the used and new PathFile #2 files was statistically significantly higher than that of the ProGlider files (P < .05). Conclusions: Within the limitations of the present study, the used glide path files' NCF, was lower than the new ones; however, this difference was not statistically significant. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier Science Inc | en_US |
dc.relation.isversionof | 10.1016/j.joen.2016.10.044 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cyclic fatigue | en_US |
dc.subject | dynamic model | en_US |
dc.subject | endodontics | en_US |
dc.subject | PathFile | en_US |
dc.subject | ProGlider | en_US |
dc.title | A Comparison of the Cyclic Fatigue Resistance of Used and New Glide Path Files | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 43 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 477 | en_US |
dc.identifier.endpage | 480 | en_US |
dc.relation.journal | Journal of Endodontics | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |