Show simple item record

dc.contributor.authorKurnaz, Cetin
dc.contributor.authorEngiz, Begum Korunur
dc.contributor.authorTurgut, Ahmet
dc.date.accessioned2020-06-21T13:27:00Z
dc.date.available2020-06-21T13:27:00Z
dc.date.issued2017
dc.identifier.isbn978-1-5090-4820-5
dc.identifier.urihttps://hdl.handle.net/20.500.12712/12687
dc.description4th International Electromagnetic Compatibility Conference (EMC Turkiye) -- SEP 24-27, 2017 -- Ankara, TURKEYen_US
dc.descriptionWOS: 000425269300016en_US
dc.description.abstractTechnological improvements and dense use of wireless systems has led to an increase in exposed electromagnetic radiation (EMR) levels in recent years. The effects of these EMRs on the population have not been completely characterized despite intense research on this topic. For this reason accurate evaluation of EMR levels in the environment have become essential. Therefore, this study aims to determine the electric field strength (E) levels on Samsun Light Rail System which can board around 90.000 passengers per day. To reach this goal; extensive E measurements were conducted on trams during the journey of total 36 stops for one week long using PMM 8053 EMR meter, and the E with a sampling period of 1 second was recorded. It is seen from the measurement results that the highest E is 5.44 V/m while the highest mean E is 0.40 V/m. Furthermore, contribution of E sources in total E determined on the basis of band selective measurements via SRM 3006 EMR meter, and the main E source is decided as cellular systems. In addition to that, the signal strengths of three existing operators for cellular systems were measured by using "NetMonitor" application.en_US
dc.description.sponsorship24-27 Sept. 2017, , Turkeyen_US
dc.language.isoengen_US
dc.publisherIeeeen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectric field strength (E)en_US
dc.subjectE measurementen_US
dc.subjectLight Rail Systemen_US
dc.subjectNetMonitor Applicationen_US
dc.subjectPMM-8053en_US
dc.subjectSRM-3006en_US
dc.titleMonitoring of the Change in Electric Field Strength Levels on Samsun Light Rail Systemen_US
dc.typeconferenceObjecten_US
dc.contributor.departmentOMÜen_US
dc.relation.journal2017 Iv International Electromagnetic Compatibility Conference (Emc Turkiye)en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record