Show simple item record

dc.contributor.authorMulazimoglu, Serkan Baris
dc.contributor.authorBeceriklisoy, Hakki Bulent
dc.contributor.authorSchafer-Somi, Sabine
dc.contributor.authorKaya, Mahir
dc.contributor.authorBumin, Ali
dc.contributor.authorOzenc, Erhan
dc.contributor.authorAslan, Selim
dc.date.accessioned2020-06-21T13:31:54Z
dc.date.available2020-06-21T13:31:54Z
dc.date.issued2016
dc.identifier.issn1300-6045
dc.identifier.urihttps://doi.org/10.9775/kvfd.2016.15686
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13046
dc.descriptionOzenc, Erhan/0000-0002-9179-8796en_US
dc.descriptionWOS: 000382113800023en_US
dc.description.abstractForty-one mammary gland tumors from twenty eight bitches were used for the study. Ultrasonographic examinations of tumor masses were performed before surgical excision and a quadratic region-of-interest (ROI) was chosen randomly on B-mode tumor images for the echotexture analyses. All tumors were evaluated histopathologically after surgery. Contrast (CONT), Mean Gradient (MG), Mean Value (MV), Homogeneity (HOM), Entropy (ENTR) and Gray Value (GV) parameters were used for the texture analyses of ultrasonographic images. Ultrasonographic image characteristics were additionally evaluated by the following macroscopic patterns: tumor shape, invasion of tumor to surrounding tissue, tumor border sharpness, echogenicity of tumor, hyperechogenic artifact, anechogenic artifact, and shadow around tumor. After B-mode ultrasonographic examination, Pulsatility Index (PI), Resistive Index (RI), Peak Systolic Flow Velocity (Vmax) and Number of Color Pixel (CP) parameters were evaluated by means of color Doppler sonography. Statistical analysis of the HOM and GV parameters indicated that there was a significant difference between benign (3.10 and 1.14) and malignant tumors (1.54 and 0.57; P< 0.01). Besides, a significant difference was found between images of Malignant-Mixed Tumors (MMT) and Benign-Mixed Tumors (BMT) with regard to CONT and HOM (p< 0.001). In addition, MV was significantly higher in malignant tumors in comparison to the benign cases (P< 0.05). A significant negative correlation was found between tumor size and MV in malignant tumor and adenocarcinoma cases (-0.991/P< 0.05; -0.999/P< 0.01, respectively). On the other hand, there was a positive correlation between tumor size and GV (0.961/P< 0.05) in malignant tumors.en_US
dc.language.isoengen_US
dc.publisherKafkas Univ, Veteriner Fakultesi Dergisien_US
dc.relation.isversionof10.9775/kvfd.2016.15686en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCanineen_US
dc.subjectMammary tumoren_US
dc.subjectDoppleren_US
dc.subjectEchotexture analysisen_US
dc.subjectUltrasounden_US
dc.titleB-mode Echotexture Analysis and Color Doppler Sonography in Canine Mammary Tumorsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume22en_US
dc.identifier.issue6en_US
dc.identifier.startpage961en_US
dc.identifier.endpage969en_US
dc.relation.journalKafkas Universitesi Veteriner Fakultesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record