Basit öğe kaydını göster

dc.contributor.authorCan, Ertugrul
dc.contributor.authorDuran, Mustafa
dc.contributor.authorCetinkaya, Tugba
dc.contributor.authorAriturk, Nursen
dc.date.accessioned2020-06-21T13:31:57Z
dc.date.available2020-06-21T13:31:57Z
dc.date.issued2016
dc.identifier.issn0974-9233
dc.identifier.issn0975-1599
dc.identifier.urihttps://doi.org/10.4103/0974-9233.194075
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13062
dc.descriptionWOS: 000389354000002en_US
dc.descriptionPubMed: 27994390en_US
dc.description.abstractAIMS: To evaluate a new noncontact optical biometer using partial-coherence interferometry and to compare the clinical measurements with those obtained from the device using optical low-coherence reflectometry (OLCR). SETTING AND DESIGN: Ondokuz Mayis University, Samsun, Turkey. Nonrandomized, prospective clinical trial SUBJECTS AND METHODS: The study was performed on the healthy phakic eyes of volunteers in the year 2014. Measurements of axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), mean keratometry (K), and white-to-white (WTW) measurements obtained with the low-time coherence interferometry (LTCI) were compared with those obtained with the OLCR. STATISTICAL ANALYSIS USED: The results were evaluated using Bland-Altman analyses. The differences between both methods were assessed using the paired t-test, and its correlation was evaluated by Pearson's coefficient. RESULTS: We examined seventy participants with a mean age of 33.06 (+/- 9.7) (range: 19-53) years. AL measurements with LTCI and OLCR were 23.7 (+/- 1.08) mm and 23.7 (+/- 1.1) mm, respectively. ACD was 3.6 (+/- 0.4) mm and 3.5 (+/- 0.4) mm for LTCI and OLCR, respectively. The mean CCT measurements for both devices were 533 (+/- 28) mm and 522 (+/- 28) mm, respectively. The mean K readings measurements for LTCI and OLCR were 43.3 (+/- 1.5) D and 43.3 (+/- 1.5) D, respectively. The mean WTW distance measurements for both devices were 12.0 (+/- 0.5) mm and 12.1 (+/- 0.5) mm, respectively. CONCLUSIONS: Measurements with LTCI correlated well with those with the OLCR. These two devices showed good agreement for the measurement of all parameters.en_US
dc.language.isoengen_US
dc.publisherMedknow Publications & Media Pvt Ltden_US
dc.relation.isversionof10.4103/0974-9233.194075en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAxial Lengthen_US
dc.subjectLow Time Coherence Interferometryen_US
dc.subjectOptical Biometeren_US
dc.subjectOptical Low-Coherence Reflectometryen_US
dc.titleComparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometersen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume23en_US
dc.identifier.issue4en_US
dc.identifier.startpage288en_US
dc.identifier.endpage292en_US
dc.relation.journalMiddle East African Journal of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster