Show simple item record

dc.contributor.authorOzyurek, Taha
dc.date.accessioned2020-06-21T13:31:59Z
dc.date.available2020-06-21T13:31:59Z
dc.date.issued2016
dc.identifier.issn0099-2399
dc.identifier.issn1878-3554
dc.identifier.urihttps://doi.org/10.1016/j.joen.2016.06.019
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13079
dc.descriptionozyurek, taha/0000-0003-3299-3361en_US
dc.descriptionWOS: 000384781300020en_US
dc.descriptionPubMed: 27520406en_US
dc.description.abstractIntroduction: The purpose of this study was to compare the cyclic fatigue resistance of Reciproc R25 (VDW, Munich, Germany), WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland), and WaveOne Gold Primary files (Dentsply Maillefer). Methods: Twenty Reciproc R25, 20 WaveOne Primary, and 20 WaveOne-Gold Primary instruments were-included in this study. The-cyclic fatigue tests were performed using a cyclic fatigue testing device, which has an artificial stainless steel canal with a 60 angle of curvature and a 5-mm radius of curvature. The files were randomly divided into 3 groups (group 1: Reciproc R25; group 2: WaveOne Primary; and group 3: WaveOne Gold Primary). All the instruments were rotated until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically (P < .05). Results: There was a significant difference among the groups (P < .05). The WaveOne Gold Primary showed the greatest mean of NCF (1628 +/- 107), and the WaveOne Primary showed the lowest mean of NCF (1153 +/- 119.2). Conclusions: Within the limitations of this in vitro study, the cyclic fatigue resistance of the WaveOne Gold Primary single-file system was higher than the WaveOne Primary and Reciproc R25 single-file instruments.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Incen_US
dc.relation.isversionof10.1016/j.joen.2016.06.019en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCyclic fatigue resistanceen_US
dc.subjectendodonticsen_US
dc.subjectReciprocen_US
dc.subjectstatic modelen_US
dc.subjectWaveOne Golden_US
dc.titleCyclic Fatigue Resistance of Reciproc, WaveOne, and WaveOne Gold Nickel-Titanium Instrumentsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume42en_US
dc.identifier.issue10en_US
dc.identifier.startpage1536en_US
dc.identifier.endpage1539en_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US