Basit öğe kaydını göster

dc.contributor.authorUslu, Gulsah
dc.contributor.authorOzyurek, Taha
dc.contributor.authorInan, Ugur
dc.date.accessioned2020-06-21T13:31:59Z
dc.date.available2020-06-21T13:31:59Z
dc.date.issued2016
dc.identifier.issn0099-2399
dc.identifier.issn1878-3554
dc.identifier.urihttps://doi.org/10.1016/j.joen.2016.07.012
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13080
dc.descriptionozyurek, taha/0000-0003-3299-3361en_US
dc.descriptionWOS: 000384781300024en_US
dc.descriptionPubMed: 27567035en_US
dc.description.abstractIntroduction: The aim of this study was to compare the cyclic fatigue resistances of nickel-titanium rotary glide path files, which are manufactured as single-file systems, under dynamic model. Methods: Twenty Pro Glider (16.02) and 20 One G (14.03) nickel-titanium glide path files were included in this study. Cyclic fatigue tests were performed with specifically manufactured dynamic cyclic testing device. The device has an artificially prepared canal with 60 curvature angle and 5-mm curvature radius. The canal inner diameter is 1.5 mm, and its curvature center is located at the corona! 5 mm from the apical. The files were randomly divided into 2 groups (n = 20): group 1, ProGlider; group 2, One G. Time to fracture was recorded, and the number of cycles to failure for each instrument was obtained. Statistical analyses were performed by using independent samples t test. The statistically significant level was set at P < .05. Results: The cyclic fatigue resistance of Pro Glider files was found to be statistically significantly higher than that of the One G files (P < .05). Conclusions: Within the limitations of the present study, it was concluded that the cyclic fatigue resistance of Pro Glider, which is manufactured as single-file glide path system, is higher than that of the One G file.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Incen_US
dc.relation.isversionof10.1016/j.joen.2016.07.012en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDynamic cyclic fatigue testen_US
dc.subjectendodonticsen_US
dc.subjectglide pathen_US
dc.subjectOne-Gen_US
dc.subjectProGlideren_US
dc.titleComparison of Cyclic Fatigue Resistance of ProGlider and One G Glide Path Filesen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume42en_US
dc.identifier.issue10en_US
dc.identifier.startpage1555en_US
dc.identifier.endpage1558en_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster