dc.contributor.author | Namli, Lutfu | |
dc.date.accessioned | 2020-06-21T13:32:16Z | |
dc.date.available | 2020-06-21T13:32:16Z | |
dc.date.issued | 2016 | |
dc.identifier.issn | 1744-2591 | |
dc.identifier.issn | 1744-2583 | |
dc.identifier.uri | https://doi.org/10.1177/1744259115624179 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12712/13163 | |
dc.description | WOS: 000382946100003 | en_US |
dc.description.abstract | In this study, effects of built-in balcony on thermal performance in residential buildings were investigated numerically by means of open-ended structure approach. For this purpose, the parametric study has been carried out for various ratios of balcony depth/balcony height (L/H), closed barrier height/balcony height (h/H) and Rayleigh numbers (Ra) using a computer program in case of no wind for laminar flow. Analyses were conducted for Rayleigh numbers ranging from 10(3) to 10(6). The calculations were carried out for the ratios of L/H, namely, 0.0, 0.24 and 0.6, and the ratios of h/H, namely, 0.0, 0.18 and 0.35. The working fluid was assumed to be air (Pr=0.71). According to the findings, for Ra10(4), Nusselt number (Nu) decreases with the increasing ratio of L/H for the constant h/H=0.35. However, for Ra10(5), Nu sharply decreases with the increasing ratio of L/H, while Nu again sharply increases after L/H0.25 and almost remains constant after L/H0.5. For the constant L/H=0.54, Nu decreases with the increasing ratio of h/H for the whole Ra. It is suggested that the ratio of L/H should not be over 0.35 and the ratio of h/H should be at least 0.35. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Sage Publications Ltd | en_US |
dc.relation.isversionof | 10.1177/1744259115624179 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Thermal performance in buildings | en_US |
dc.subject | balcony | en_US |
dc.subject | open-ended structure | en_US |
dc.subject | extended boundaries | en_US |
dc.subject | laminar natural convection in enclosure | en_US |
dc.title | Effects of built-in balcony on thermal performance in residential buildings: A case study | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 40 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 125 | en_US |
dc.identifier.endpage | 143 | en_US |
dc.relation.journal | Journal of Building Physics | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |