dc.description.abstractTo describe a novel technique for implantation of intraocular lens in the absence of capsular support using a ciliary sulcus guide. Based on the anatomic knowledge of the ciliary sulcus and the sclera, a new instrument was developed to pierce the needle safely through the ciliary sulcus and sclera. While the foldable lens is stored inside the cartridge, the leading haptic is sutured with a cow-hitch knot. The needle is then inserted into the ciliary sulcus guide. The tip of the guide is inserted from the corneal incision and proceeded under the iris to touch and fit the ciliary sulcus. The needle is pushed from back side. The needle comes out at precise point at the sclera. Implantation of the lens was performed through a 2.8 mm clear cornea incision using the injector. The trailing haptic is tied after implantation, and then the same procedure is performed at the opposite side. We performed this technique to 15 aphakic eyes without sufficient capsular support. There was no bleeding or other intraoperative complication. All the points coming out the sclera were between 2 and 2.5 mm from the limbus. The ab interno technique for scleral fixation of IOL is quicker, easier and less traumatic then ab externo techniques. A new ciliary sulcus guide which is usable with both straight and curved needles eliminates the blind maneuvers of ab interno technique and makes this technique more safe and precise.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.isversionof10.1007/s10792-015-0132-0en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectScleral fixationen_US
dc.subjectCiliary sulcus guideen_US
dc.subjectAphakiaen_US
dc.titleA safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guideen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume36en_US
dc.identifier.issue4en_US
dc.identifier.startpage463en_US
dc.identifier.endpage468en_US
dc.relation.journalInternational Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster