Basit öğe kaydını göster

dc.contributor.authorCan, Ertugrul
dc.contributor.authorDuran, Mustafa
dc.contributor.authorCetinkaya, Tugba
dc.contributor.authorAriturk, Nursen
dc.date.accessioned2020-06-21T13:33:47Z
dc.date.available2020-06-21T13:33:47Z
dc.date.issued2016
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.urihttps://doi.org/10.1007/s10792-015-0097-z
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13413
dc.descriptionWOS: 000373181000004en_US
dc.descriptionPubMed: 26115695en_US
dc.description.abstractThe purpose of this study was to investigate the effects of pupil dilation on the parameters of the AL-Scan (Nidek Co., Ltd, Gamagori, Japan). We compared the measurements of axial length (AL), anterior chamber depth (ACD), central corneal keratometry reading, pupil diameter, and intraocular lens (IOL) power of 72 eyes of 72 healthy volunteers and patients scheduled for cataract surgery before and 45 min after instillation of cyclopentolate hydrochloride 1 % using the AL-Scan. Intraobserver repeatability was assessed by taking three consecutive recordings of ACD and AL. Only ACD readings were significantly different between predilation and postdilation (P < 0.001). The difference of the other measurements between two sessions was not statistically significant (P > 0.001). Only two cases in the study demonstrated changes in IOL power higher than 0.5 D. The intraobserver repeatability of both devices was good (CV values for ACD and AL were 0.16 and 0.20 %, respectively). Dilated pupil size did not affect the measurement of IOL power using the A-Scan optical biometer, but increase in ACD after dilation should be taken into account when performing refractive surgeries in which ACD is very important such as phakic anterior chamber IOL implantation.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.isversionof10.1007/s10792-015-0097-zen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOptical biometryen_US
dc.subjectAxial lengthen_US
dc.subjectAnterior chamber depthen_US
dc.subjectAL-Scanen_US
dc.titleThe effect of pupil dilation on AL-Scan biometric parametersen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume36en_US
dc.identifier.issue2en_US
dc.identifier.startpage179en_US
dc.identifier.endpage183en_US
dc.relation.journalInternational Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster