dc.contributor.author | Oz, Abdullah Alper | |
dc.contributor.author | Oz, Aslihan Zeynep | |
dc.contributor.author | Arici, Selim | |
dc.date.accessioned | 2020-06-21T13:39:16Z | |
dc.date.available | 2020-06-21T13:39:16Z | |
dc.date.issued | 2016 | |
dc.identifier.issn | 0889-5406 | |
dc.identifier.issn | 1097-6752 | |
dc.identifier.uri | https://doi.org/10.1016/j.ajodo.2015.07.036 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12712/13517 | |
dc.description | Arici, Selim/0000-0001-8890-2065 | en_US |
dc.description | WOS: 000369693700011 | en_US |
dc.description | PubMed: 26827977 | en_US |
dc.description.abstract | Introduction: The purpose of this study was to compare the clinical failure rates and the in-vitro bond strengths of metal brackets bonded with different light-emitting diode (LED) devices and curing times. Methods: Forty patients were included in the clinical part of this study. A split-mouth design was used, with the adhesive in group 1 cured for 10 seconds with an LED unit (Elipar S10; 3M Unitek, Monrovia, Calif), and the adhesive in group 2 cured for 3 seconds with another LED unit (VALO Ortho; Ultradent Products, South Jordan, Utah). Bond failures during 12 months of orthodontic treatment were recorded. In-vitro performance of the brackets was also compared by bonding brackets to extracted premolars and using the same light units and curing times (n = 20 for each group). The adhesive remnant index was used to determine the bond failure interface. Results: Clinical bond failure rates were 2.90% for the Elipar and 3.16% for the VALO curing units. The difference in bracket failure rates between the 2 LED devices was not statistically significant. No statistically significant difference was found between the in-vitro bond strengths of the groups. Conclusions: Our findings regarding long-term clinical survival rates and in-vitro bond strengths indicate that bracket bonding can be safely accomplished in 10 seconds of light-curing with an Elipar LED and 3 seconds of light-curing with a VALO LED. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Mosby-Elsevier | en_US |
dc.relation.isversionof | 10.1016/j.ajodo.2015.07.036 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.title | In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 149 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 212 | en_US |
dc.identifier.endpage | 216 | en_US |
dc.relation.journal | American Journal of Orthodontics and Dentofacial Orthopedics | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |