Show simple item record

dc.contributor.authorSumer, A. P.
dc.contributor.authorCaliskan, A.
dc.contributor.authorUzun, C.
dc.contributor.authorKaroz, T. B.
dc.contributor.authorSumer, M.
dc.contributor.authorCankaya, S.
dc.date.accessioned2020-06-21T13:39:17Z
dc.date.available2020-06-21T13:39:17Z
dc.date.issued2016
dc.identifier.issn0901-5027
dc.identifier.issn1399-0020
dc.identifier.urihttps://doi.org/10.1016/j.ijom.2015.09.012
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13521
dc.descriptionWOS: 000369464300015en_US
dc.descriptionPubMed: 26458537en_US
dc.description.abstractThe palate is an alternative anchoring site for orthodontic implants and screws. The use of osseointegrated implants in the intermaxillary suture has recently been described as a fast, effective, and low-cost technique for patients with atrophy of the maxillae. The aim of this study was to use cone beam computed tomography (CBCT) to evaluate the thickness of the bone surrounding the intermaxillary suture in relation to the insertion of osseointegrated implants. CBCT images of 144 patients (72 males, 72 females) aged 35-86 years were evaluated. The vertical bone height of the intermaxillary suture was measured using coronal and sagittal Images 5, 10, 15, 20, and 25 mm posterior to the incisive foramen. The mean bone thicknesses from the anterior to the posterior region were 5.59, 4.38, 3.91, 3.95, and 3.94 mm, respectively. Bone thickness was significantly different among the five anteroposterior areas of the suture, but there were no significant differences between males and females, or among age groups. The highest part of the intermaxillary suture was in the anterior region. Three-dimensional imaging is recommended to accurately identify palate bone thickness for implant placement.en_US
dc.language.isoengen_US
dc.publisherChurchill Livingstoneen_US
dc.relation.isversionof10.1016/j.ijom.2015.09.012en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCBCTen_US
dc.subjectpalatal implantsen_US
dc.subjectpalateen_US
dc.titleThe evaluation of palatal bone thickness for implant insertion with cone beam computed tomographyen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume45en_US
dc.identifier.issue2en_US
dc.identifier.startpage216en_US
dc.identifier.endpage220en_US
dc.relation.journalInternational Journal of Oral and Maxillofacial Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record