dc.contributor.author | Ozlu, Fethiye Cakmak | |
dc.contributor.author | Kocak, Sibel | |
dc.contributor.author | Kocak, Mustafa Murat | |
dc.contributor.author | Elekdag-Turk, Selma | |
dc.contributor.author | Turk, Tamer | |
dc.date.accessioned | 2020-06-21T13:45:41Z | |
dc.date.available | 2020-06-21T13:45:41Z | |
dc.date.issued | 2015 | |
dc.identifier.issn | 2528-9659 | |
dc.identifier.issn | 2148-9505 | |
dc.identifier.uri | https://doi.org/10.5152/TurkJOrthod.2016.15-00006R2 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12712/14152 | |
dc.description | Turk, Tugba/0000-0002-3726-3715 | en_US |
dc.description | WOS: 000439316200001 | en_US |
dc.description.abstract | Objective: To evaluate the initial shear bond strengths (SBSs) of ceramic brackets using either a self-etching primer (SEP) or the conventional method (CM) after intracoronal bleaching with sodium perborate and distilled water. Methods: Eighty human incisors were divided into four groups according to bleaching and bonding procedures: Group 1, bleaching was not applied and the brackets were bonded with a self-etching primer; Group 2, bleaching was not applied and the brackets were bonded with the conventional method; Group 3, intracoronal bleaching with sodium perborate was applied for three weeks and the brackets were bonded with a self-etching primer; and Group 4, intracoronal bleaching with sodium perborate was applied for three weeks and the brackets were bonded with the conventional method. A self-etching primer (Transbond Plus) was applied as recommended by the manufacturer. After SEP application, the ceramic brackets were bonded with a light-curing adhesive (Transbond XT). For the conventional method, the teeth were etched with 37% phosphoric acid. After etching, a thin uniform coat of primer (Transbond XT Primer) was applied and the ceramic brackets were bonded with a light-curing adhesive (Transbond XT). SBSs were measured after water storage for 30 days, after 1000 cycles of thermocycling between 5 degrees C and 55 degrees C. Bond failure location was determined with the Adhesive Remnant Index (ARI). Results: For the SEP method, there was no significant difference between SBS values of the bleaching and non-bleaching groups. Furthermore, for the conventional method, the SBS value of the non-bleaching group was not significantly different from that of the bleaching group. SBS values of the SEP method presented significant differences from those of the conventional method (p<0.001). SBS values of SEP application decreased with and without bleaching. The ARI scores did not show any significant difference among the groups (p=0.174). Conclusion: Intracoronal bleaching with sodium perborate and distilled water did not affect the SBS values of ceramic brackets. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Aves Press Ltd | en_US |
dc.relation.isversionof | 10.5152/TurkJOrthod.2016.15-00006R2 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Self-etching primer | en_US |
dc.subject | intracoronal bleaching | en_US |
dc.subject | ceramic brackets | en_US |
dc.subject | bond strength | en_US |
dc.title | Comparison of the Shear Bond Strengths of Ceramic Brackets Using Either a Self-Etching Primer or the Conventional Method after Intracoronal Bleaching | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 28 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 77 | en_US |
dc.identifier.endpage | 81 | en_US |
dc.relation.journal | Turkish Journal of Orthodontics | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |