Basit öğe kaydını göster

dc.contributor.authorEren, Hilal
dc.contributor.authorUzun, Harun
dc.contributor.authorAndac, Muberra
dc.contributor.authorBilir, Seda
dc.date.accessioned2020-06-21T13:52:20Z
dc.date.available2020-06-21T13:52:20Z
dc.date.issued2014
dc.identifier.issn1021-9498
dc.identifier.urihttps://doi.org/10.1016/j.jfda.2014.03.003
dc.identifier.urihttps://hdl.handle.net/20.500.12712/14859
dc.descriptionANDAC, Muberra/0000-0001-7262-9762en_US
dc.descriptionWOS: 000346623500003en_US
dc.descriptionPubMed: 28911454en_US
dc.description.abstractA new solid contact cobalt selective electrode was constructed with 4-tert-butylthiacalix[4] arene as ionophore. The best performance was observed with the membrane having an ionophore/polyvinyl chloride/sodium tetraphenylborate/nitrophenyl octyl ether ratio of 3.5:33:1.5:62 (w/w; mg). The electrode, under steady-state conditions, exhibited a working concentration range of 1 x 10(-1) - 1 x 10(-6) mol/L with a near-Nernstian slope of 25.3 mV/decade and a detection limit of 3.5 x 10(-7) mol/L. The electrode had a very short response time (<10 seconds) and good reproducibility at a working pH range of 4.0-6.5. The electrode was used for 4 months without any significant change in its sensitivity. The potentiometric performance of the electrode in partially nonaqueous medium [up to 20 % (v/v) alcohol] was found satisfactory. The performance of the prepared electrode for the analysis of beer samples using direct potentiometric method is very encouraging. Copyright (C) 2014, Food and Drug Administration, Taiwan. Published by Elsevier Taiwan LLC. All rights reserved.en_US
dc.description.sponsorshipOndokuz Mayis University Research Foundation (BAP), Kurupelit-Samsun, TurkeyOndokuz Mayis University [PYO.Fen. 1904.11.019]en_US
dc.description.sponsorshipWe gratefully acknowledge the financial support of Ondokuz Mayis University Research Foundation (BAP), Kurupelit-Samsun, Turkey (Project number PYO.Fen. 1904.11.019).en_US
dc.language.isoengen_US
dc.publisherFood & Drug Adminstrationen_US
dc.relation.isversionof10.1016/j.jfda.2014.03.003en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBeeren_US
dc.subjectCobalten_US
dc.subjectPolyvinyl chloride (PVC) membraneen_US
dc.subjectPotentiometryen_US
dc.subjectSolid contacten_US
dc.titlePotentiometric monitoring of cobalt in beer sample by solid contact ion selective electrodeen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume22en_US
dc.identifier.issue4en_US
dc.identifier.startpage413en_US
dc.identifier.endpage417en_US
dc.relation.journalJournal of Food and Drug Analysisen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster