Show simple item record

dc.contributor.authorAndac, Muberra
dc.contributor.authorColdur, Fatih
dc.contributor.authorBilir, Seda
dc.contributor.authorBirinci, Aysenur
dc.contributor.authorDemir, Serkan
dc.contributor.authorUzun, Harun
dc.date.accessioned2020-06-21T13:57:30Z
dc.date.available2020-06-21T13:57:30Z
dc.date.issued2014
dc.identifier.issn0008-4042
dc.identifier.issn1480-3291
dc.identifier.urihttps://doi.org/10.1139/cjc-2013-0530
dc.identifier.urihttps://hdl.handle.net/20.500.12712/15223
dc.descriptionANDAC, Muberra/0000-0001-7262-9762en_US
dc.descriptionWOS: 000334031500009en_US
dc.description.abstractA miniaturized solid-contact polyvinyl chloride membrane electrode based on the bis[(2-(hydroxyethylimino)phenolato]copper(II) complex has been prepared for the determination of Cu(II) ion in real samples. The influence of coating membrane composition, pH, and possible interfering cations on the response of the ion-selective electrode was investigated. A number of membranes at different compositions were prepared and their Cu2+ sensing capabilities were investigated. The best results for Cu2+ sensing was obtained for the electrode membrane containing ionophore -2-nitrophenyloctyl ether - polyvinyl chloride and potassium tetrakis(p-chlorophenyl) borate in a ratio of 4:65:30:1 (w/w, mg), respectively. The prepared electrode exhibited a near-Nernstian response (28.3 mV/decade) to Cu2+ in the concentration range from 1.0 x 10(-6) to 1.0 x 10(-1) mol/L with a limit of detection of 8.3 x 10(-7) mol/L. The potentiometric response of the electrode was independent from the pH of the test solution in the pH range of 3.0-6.0. The electrode has a very short response time, about 15 s, and it can be used over a period of 3 months without any divergence in potential. The electrode has been successfully applied as an indicator electrode in potentiometric titration of Cu(II) ions with ethylenediaminetetraacetic acid and in the determination of Cu(II) in wastewater of the copper processing industry.en_US
dc.description.sponsorshipOndokuz Mayis University Research Foundation (BAP) ProjectOndokuz Mayis University [PYO.Fen.1904.10.034]en_US
dc.description.sponsorshipThis work was supported by the Ondokuz Mayis University Research Foundation (BAP) Project (PYO.Fen.1904.10.034).en_US
dc.language.isoengen_US
dc.publisherCanadian Science Publishingen_US
dc.relation.isversionof10.1139/cjc-2013-0530en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectpotentiometryen_US
dc.subjectcopper selective electrodesen_US
dc.subjectwastewater analysisen_US
dc.titleSolid-contact polyvinyl chloride membrane electrode based on the bis[(2-(hydroxyethylimino)phenolato]copper(II) complex for trace level determination of copper ions in wastewateren_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume92en_US
dc.identifier.issue4en_US
dc.identifier.startpage324en_US
dc.identifier.endpage328en_US
dc.relation.journalCanadian Journal of Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record