• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Correction of saturated current from measurement current transformer

Date

2013

Author

Ozgonenel, Okan

Metadata

Show full item record

Abstract

The suggested study presents an easy and effective way to compensate for the distorted secondary current of measurement-type current transformers (CTs). The suggested compensating algorithm is based on estimating the magnetising current from a Frohlich hysteresis approach. The efficiency of the proposed technique was first proved using computer simulations. The prototype compensating device was then tested in a laboratory environment using a 5/1A, 10VA, C0,5 measurement-type CT. The proposed compensation algorithm is dependent on CT burden and X/R ratio of the line where CT is connected. The outcomes of the study demonstrate that the technique is able to reconstruct the secondary current with an acceptable error and can be applied to any measurement-type CT regardless of its size and winding topology.

Source

Iet Electric Power Applications

Volume

7

Issue

7

URI

https://doi.org/10.1049/iet-epa.2013.0105
https://hdl.handle.net/20.500.12712/15743

Collections

  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]

Related items

Showing items related by title, author, creator and subject.

  • Comparison of DC link current and stator phase current in inverter switching faults detection of PMSM drives in HEVs 

    Aktas, Mustafa; Aygun, Hilmi (Elsevier - Division Reed Elsevier India Pvt Ltd, 2018)
    In this paper, a robust method for detection of inverter short circuit faults in field oriented control (FOC) of permanent magnet synchronous motor (PMSM) drive that is used frequently in hybrid electric vehicles (HEV) ...
  • A different algorithm for correcting secondary current of current transformer 

    Ozgonenel O.; Terzi U.K.; Guney I. (2010)
    This work is about the negative effects of protection devices during current transformer (CT) saturation because the performance of the protection devices such as differential and impedance relays is mainly based on the ...
  • Low input impedance current-mode allpass and notch filter employing single current follower 

    Ergun, E.; Ulutas, M. (Technical Univ Lodz, 2007)
    A new current-mode low input impedance second order allpass and notch filter with single current follower was proposed in this work. Circuit contains one dual output current-follower, two capacitors and four resistors. ...



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Ondokuz Mayıs

by OpenAIRE

Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Library || Ondokuz University || OAI-PMH ||

Ondokuz Mayıs University, Samsun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Ondokuz University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.