Show simple item record

dc.contributor.authorChan, Daniel S.
dc.contributor.authorBurris, Richard B.
dc.contributor.authorErdogan, Murat
dc.contributor.authorSagi, H. Claude
dc.date.accessioned2020-06-21T14:05:07Z
dc.date.available2020-06-21T14:05:07Z
dc.date.issued2013
dc.identifier.issn0890-5339
dc.identifier.urihttps://doi.org/10.1097/BOT.0b013e3182828e10
dc.identifier.urihttps://hdl.handle.net/20.500.12712/15779
dc.descriptionWOS: 000322018400007en_US
dc.descriptionPubMed: 23287748en_US
dc.description.abstractObjective: This study was designed to compare the accuracy, time, and radiation exposure during the insertion of intramedullary nail locking screws using either standard fluoroscopic assistance or an electromagnetic (EM)-based navigational system without fluoroscopy.Design: Prospective.Setting: Level I academic trauma center.Methods: Patients were divided into 2 groups: group 1 (fluoroscopic assistance), consisted of standard freehand fluoroscopically assisted insertion of locking screws (OEC 9900; G.E. HealthCare, Waukesha, WI), whereas group 2 (EM), consisted of EM navigationally assisted insertion without fluoroscopy (SureShot; Smith & Nephew, Memphis, TN). Technician arrival time, setup (SU) time, screw insertion (SI) time (seconds), fluoroscopy time (seconds), radiation exposure (mrads), and accuracy (hit or miss) were recorded for each screw. For group 1, the SU time was recorded as the time and radiation required to obtain perfect circles before insertion, and for group 2, the SU time was recorded as the time required to set up the navigational EM unit. Data collected regarding SI were then compared using standard analysis of variance.Results: Forty-one locking screws were inserted in group 1, whereas 60 screws were inserted in group 2. Accuracy was 100% for both groups. For group 1, mean technician wait time was 77 seconds plus a mean perfect circle SU time of 105 seconds (9.2 mrads and 10 seconds of fluoroscopy). Mean SU time for group 2 was 94 seconds (no fluoroscopy). Mean insertion time was 342 seconds per screw for group 1 (32.9 mrads and 18 seconds of fluoroscopy) compared with 234 seconds per screw for group 2 (no fluoroscopy). These differences were statistically significant (P = 0.006).Conclusions: The use of EM navigation (SureShot; Smith & Nephew) for the insertion of intramedullary nail locking screws demonstrated accuracy similar to conventional fluoroscopic-guided insertion. However, EM-guided locking SI resulted in a significantly shorter total procedural time and completely eliminated radiation exposure.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.isversionof10.1097/BOT.0b013e3182828e10en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIMNen_US
dc.subjectfluoroscopyen_US
dc.subjectradiationen_US
dc.subjectlocking screwen_US
dc.subjectelectromagneticen_US
dc.subjectSureShoten_US
dc.titleThe Insertion of Intramedullary Nail Locking Screws Without Fluoroscopy: A Faster and Safer Techniqueen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume27en_US
dc.identifier.issue7en_US
dc.identifier.startpage363en_US
dc.identifier.endpage366en_US
dc.relation.journalJournal of Orthopaedic Traumaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)