Basit öğe kaydını göster

dc.contributor.authorKaraman, E.
dc.contributor.authorYazici, A. R.
dc.contributor.authorTuncer, D.
dc.contributor.authorFirat, E.
dc.contributor.authorUnluer, S.
dc.contributor.authorBaseren, M.
dc.date.accessioned2020-06-21T14:05:10Z
dc.date.available2020-06-21T14:05:10Z
dc.date.issued2013
dc.identifier.issn0361-7734
dc.identifier.issn1559-2863
dc.identifier.urihttps://doi.org/10.2341/12-181-C
dc.identifier.urihttps://hdl.handle.net/20.500.12712/15787
dc.descriptionWOS: 000321319400005en_US
dc.descriptionPubMed: 23210859en_US
dc.description.abstractAim: To compare the retention rates of a nanofilled occlusal fissure sealant placed with the use of an etch-and-rinse or a self-etch adhesive over 48 months. Materials and Methods: The authors enrolled 244 teeth, each with no restoration or sealant and no detectable caries, from 16 patients. The sealants were placed with Solobond M two-step etch-and-rinse adhesive or Futurabond NR one-step self-etch adhesive by four previously calibrated dentists using a table of random numbers. After completion of the adhesive application, a nanofilled sealant, Grandio Seal, was applied and light-cured. Two other calibrated examiners, who were unaware of which adhesive had been used, independently evaluated the sealants at baseline and at 12-, 24-, 36-, and 48-month recalls. Each sealant was evaluated in terms of caries formation being present or absent and retention using the following criteria: 1 = completely retained, 2 = partial loss, and 3 = total loss. ThePearson chi(2) test was used to evaluate differences in retention rates among the sealants used with different adhesives for each evaluation period. Results: The retention rates for sealants in the Solobond M group were significantly higher than those in the Futurabond NR group in all periods of evaluation (p<0.05). No statistically significant difference between the retention rates for premolars and molars was found at each evaluation period (p>0.05). There was no new caries formation throughout the 48-month recall period. Conclusion: Fissure sealants placed with etch-and-rinse adhesive showed better retention rates than those placed with self-etch adhesive.en_US
dc.language.isoengen_US
dc.publisherOperative Dentistry Incen_US
dc.relation.isversionof10.2341/12-181-Cen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleA 48-month Clinical Evaluation of Fissure Sealants Placed With Different Adhesive Systemsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume38en_US
dc.identifier.issue4en_US
dc.identifier.startpage369en_US
dc.identifier.endpage375en_US
dc.relation.journalOperative Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster