dc.description.abstractBackground: The aim of this study was to evaluate the microtensile bond strength (mu TBS) of a new fissure sealant and compare it with conventional sealants which are applied to enamel alone, and also with self-etch and etch-and-rinse adhesives. Methods: Enamel specimens were prepared and randomly distributed into three groups according to fissure sealant (Aegis, Helioseal F, Helioseal Clear). Each group was then subdivided according to adhesive system (Clearfil S3, Single Bond, no adhesive). A universal testing machine was used to measure lTBS, and data were analysed using one- way ANOVA and Tukey's tests. Results: lTBS values for all Aegis subgroups were significantly lower than for comparable Helioseal F and Helioseal Clear subgroups (p < 0.05). No differences were observed in lTBS of Helioseal F and Helioseal Clear (p > 0.05). In the Helioseal Clear group, lTBS values for Single Bond were significantly higher than for Clearfil S3 (p < 0.05). However, no significant differences were found between the lTBS values of the adhesive subgroups in the Aegis or Helioseal F groups (p > 0.05). Conclusions: Sealant lTBS values may be affected by material content. The addition of an adhesive may improve lTBS values of sealant to enamel.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.relation.isversionof10.1111/j.1834-7819.2011.01639.xen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAdhesive systemsen_US
dc.subjectamorphous calcium phosphateen_US
dc.subjectbond strengthen_US
dc.subjectfissure sealantsen_US
dc.subjectpreventive dentistryen_US
dc.titleEvaluation of microtensile bond strength of different fissure sealants to bovine enamelen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume57en_US
dc.identifier.issue1en_US
dc.identifier.startpage79en_US
dc.identifier.endpage84en_US
dc.relation.journalAustralian Dental Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record