dc.description.abstractIntroduction: A number of rotary nickel-titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system, and recently, rotary NiTi systems designed for root canal retreatment have been introduced. Because the main problem with the rotary NiTi files is fracture, the aim of this study was to compare the cyclic fatigue resistance of 3 different rotary NiTi systems designed for root canal retreatment. Methods: Total of 60 instruments of 3 different rotary NiTi systems designed for root canal retreatment were used in this study. Twenty R-Endo R3, 20 ProTaper D3, and 20 Mtwo R (Retreatment) 25.05 instruments were tested. Cyclic fatigue testing of instruments was performed by using a device that allowed the instruments to rotate freely inside an artificial canal. Each instrument was rotated until fracture occurred, and the number of cycles to fracture for each instrument was calculated. Representative samples were also evaluated under a scanning electron microscope to confirm the fracture was flexural. Data were analyzed by using 1-way analysis of variance test. Results: R-Endo R3 instruments showed better cyclic fatigue resistance than ProTaper D3 and Mtwo R 25.05 instruments, and the difference was statistically significant (P < .05). There was no significant difference between ProTaper D3 and Mtwo R 25.05 groups. Conclusions: The R-Endo R3 instruments were more resistant to fatigue failure than ProTaper D3 and Mtwo R 25.05. (J Endod 2012;38:108-111)en_US
dc.description.sponsorshipTUBITAKTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [109S019]en_US
dc.description.sponsorshipSupported by TUBITAK Short Term Funding Programme project no. 109S019.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Incen_US
dc.relation.isversionof10.1016/j.joen.2011.09.010en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCyclic fatigueen_US
dc.subjectnickel-titaniumen_US
dc.subjectretreatmenten_US
dc.titleComparison of Cyclic Fatigue Resistance of Three Different Rotary Nickel-Titanium Instruments Designed for Retreatmenten_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume38en_US
dc.identifier.issue1en_US
dc.identifier.startpage108en_US
dc.identifier.endpage111en_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US