Basit öğe kaydını göster

dc.contributor.authorAndac, Muberra
dc.contributor.authorEren, Hilal
dc.contributor.authorColdur, Fatih
dc.date.accessioned2020-06-21T14:29:28Z
dc.date.available2020-06-21T14:29:28Z
dc.date.issued2011
dc.identifier.issn1021-9498
dc.identifier.urihttps://hdl.handle.net/20.500.12712/16905
dc.descriptionANDAC, Muberra/0000-0001-7262-9762en_US
dc.descriptionWOS: 000298774100010en_US
dc.description.abstractA rapid, simple and inexpensive flow injection potentiometric method for the determination of nitrate in leafy vegetables is described. Six commonly consumed fresh leafy vegetables (mint, lettuce, savoy cabbage, stinging nettle, parsley and cress) were obtained from bazaar in Samsun. An all-solid-state miniaturized nitrate-selective electrode was used as a detector in a low-dead-volume flow through cell. Nitrate was determined in the linear range from 0.1 to 100 mmol/L with detection limit of 0.066 mmol/L. The calibration slope is 52.96 +/- 1.02 mV/decade in the linear range. The relative standard deviation (RSD) of the electrode response of 100, 10 and 1 mmol/L NO3- was 0.46, 0.49 and 0.98%, respectively. The flow injection analysis (FIA) throughput was 90 samples/h. The FIA results were compared with those obtained by spectrophotometric method. The results of the study show that nitrate contents in fresh leafy vegetables ranged from 97 to 1861 mg/kg.en_US
dc.description.sponsorshipOndokuz Mayis University Research Foundation (BAP)Ondokuz Mayis University [PYO. Fen.1901.10.002]en_US
dc.description.sponsorshipThis work was supported by the Ondokuz Mayis University Research Foundation (BAP) Project (PYO. Fen.1901.10.002).en_US
dc.language.isoengen_US
dc.publisherBureau Food Drug Analysisen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectnitrate in vegetablesen_US
dc.subjectleafy vegetablesen_US
dc.subjectflow injection potentiometryen_US
dc.subjectnitrate-selective electrodesen_US
dc.subjectsolid-contact ion-selective electrodesen_US
dc.titleDetermination of Nitrate in Leafy Vegetables by Flow Injection Analysis with Potentiometric Detectionen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume19en_US
dc.identifier.issue4en_US
dc.identifier.startpage457en_US
dc.identifier.endpage462en_US
dc.relation.journalJournal of Food and Drug Analysisen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster