Basit öğe kaydını göster

dc.contributor.authorColdur, Fatih
dc.contributor.authorAndac, Muberra
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2020-06-21T14:46:41Z
dc.date.available2020-06-21T14:46:41Z
dc.date.issued2010
dc.identifier.issn1432-8488
dc.identifier.urihttps://doi.org/10.1007/s10008-010-1070-4
dc.identifier.urihttps://hdl.handle.net/20.500.12712/17635
dc.description10th Annual Meeting on Advanced Batteries and Accumulators (ABA-10) -- 2009 -- Brno, CZECH REPUBLICen_US
dc.descriptionANDAC, Muberra/0000-0001-7262-9762en_US
dc.descriptionWOS: 000284161300016en_US
dc.description.abstractA solid state polyvinyl chloride (PVC) membrane Li+-selective electrode was prepared and used as a detector in a low-dead volume flow through cell for the determination of Li+ in pharmaceutical formulations and human serum samples. The potentiometric performance characteristics of the electrode were calculated under the optimized flow conditions. The electrode had near-Nernstian behavior in the concentration range of 0.1-100 mM (R (2) = 0.9981) with a slope of 61.34 mV decade(-1) and detection limit of 0.080 mM. The relative standard deviation of the electrode response for eight replicate measurements of 100, 10, and 1 mM Li+ was 0.43%, 0.45%, and 0.99%, respectively. The designed flow-through cell detector system revealed sampling rates of approximately 70 injections per hour. Flow injection potentiometry (FIP) results obtained for the pharmaceutical formulations were in good harmony with the atomic emission spectrophotometry results. However, the electrode could not be used successfully for the direct analysis of real serum samples in FIP.en_US
dc.description.sponsorshipBrno Tech Univ, Fac Elect Engn & Commun Technologen_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.isversionof10.1007/s10008-010-1070-4en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAll-solid state lithium-selective electrodeen_US
dc.subjectSolid-contact ion-selective electrodeen_US
dc.subjectFlow injection potentiometryen_US
dc.subjectSerum analysisen_US
dc.subjectPharmaceutical formulationsen_US
dc.titleFlow-injection potentiometric applications of solid state Li+ selective electrode in biological and pharmaceutical samplesen_US
dc.typeconferenceObjecten_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume14en_US
dc.identifier.issue12en_US
dc.identifier.startpage2241en_US
dc.identifier.endpage2249en_US
dc.relation.journalJournal of Solid State Electrochemistryen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster