Basit öğe kaydını göster

dc.contributor.authorErdem, Dilek Gurgenyatagi
dc.contributor.authorErdem, Emre
dc.contributor.authorDilek, Melda
dc.contributor.authorAydogdu, Turkan
dc.contributor.authorSelim, Nevzat
dc.contributor.authorDemiray, Feride
dc.contributor.authorAkpolat, Tekin
dc.date.accessioned2020-06-21T15:08:34Z
dc.date.available2020-06-21T15:08:34Z
dc.date.issued2009
dc.identifier.issn1420-4096
dc.identifier.issn1423-0143
dc.identifier.urihttps://doi.org/10.1159/000228936
dc.identifier.urihttps://hdl.handle.net/20.500.12712/18989
dc.descriptionWOS: 000270553600001en_US
dc.descriptionPubMed: 19622898en_US
dc.description.abstractBackground/Aims: The aims of this study are to assess the reasons of using sphygmomanometers at pharmacies and to evaluate their accuracy. Methods: 135 devices ( 118 aneroid, 1 mercury, and 16 automated) from 125 pharmacies ( located in Samsun city center) were included in the study. A non-randomized, cross-sectional design was used for the study protocol which had two parts: assessment of devices and a questionnaire about the pharmacy and present sphygmomanometer(s). Results: 40 (30%) of the 135 sphygmomanometers were inaccurate. 65 (48%) of the devices were older than 1 year and there was no correlation between the duration of the ownership of the sphygmomanometers and their inaccuracy (p > 0.05). Blood pressure measurement is a frequent practice at pharmacies. The aneroid type of sphygmomanometers was common. A limited number of devices were checked for accuracy before. The number of validated devices was low. Conclusion: Training programs for pharmacists including the accuracy of sphygmomanometers and regular checks of sphygmomanometers for accuracy will be beneficial to the community and to the subjects requesting measurement of blood pressure at the pharmacies. Copyright (c) 2009 S. Karger AG, Baselen_US
dc.language.isoengen_US
dc.publisherKargeren_US
dc.relation.isversionof10.1159/000228936en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBlood pressureen_US
dc.subjectHypertensionen_US
dc.subjectSphygmomanometer, pharmaciesen_US
dc.subjectPharmacy sphygmanometers, accuracyen_US
dc.titleAccuracy of Sphygmanometers at Pharmaciesen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume32en_US
dc.identifier.issue4en_US
dc.identifier.startpage231en_US
dc.identifier.endpage234en_US
dc.relation.journalKidney & Blood Pressure Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster