Basit öğe kaydını göster

dc.contributor.authorNural, Mehmet Selim
dc.contributor.authorCeyhan, Meltem
dc.contributor.authorBaydin, Ahmet
dc.contributor.authorGenc, Selim
dc.contributor.authorBayrak, Ilkay Koray
dc.contributor.authorElmali, Muzaffer
dc.date.accessioned2020-06-21T15:12:46Z
dc.date.available2020-06-21T15:12:46Z
dc.date.issued2008
dc.identifier.issn1828-0447
dc.identifier.urihttps://doi.org/10.1007/s11739-008-0157-8
dc.identifier.urihttps://hdl.handle.net/20.500.12712/19090
dc.descriptionBAYDIN, AHMET/0000-0003-4987-0878en_US
dc.descriptionWOS: 000264318600009en_US
dc.descriptionPubMed: 18443745en_US
dc.description.abstractOur aim was to assess the effects of initial ultrasonography (US) evaluation on the diagnosis and management of non-traumatic acute abdominal pain in the emergency department. Three hundred patients with the complaint of non-traumatic acute abdominal pain who were sent for US examination with an initial clinical impression were included in the study. Pre-US and post-US surveys were designed for the clinicians who requested US. The percentage concordance of US findings with the discharge diagnosis made by clinical follow-up, imaging modalities and surgery was determined by calculating the confidence interval. The concordance of the initial clinical impression and the US diagnosis with the discharge diagnosis were compared using the McNemar test. US could not detect any pathology in 102 (34%; 95% CI, 28.6-39.3%) of the patients. The US revealed a different diagnosis than the clinical impression in 69 (23%; 95% CI, 18.2-27.7%), and confirmed the diagnosis in 121 (40%; 95% CI, 34.4-45.5%) patients. The US changed the treatment plans in 47% (95% CI, 41.3-52.6%) of the patients. The clinicians stated US helped them "very much'' or "moderately'' in making a diagnosis in 83% (95% CI, 78.7-87.2%). When US results were compared with the discharge diagnosis, there was concordance in 238 (79.3%; 95% CI, 74.3-83.6%) patients but not in 62 (20.6%; 95% CI, 16-25.1%). Among 121 patients the initial clinical impression agreed with the US diagnosis and there was concordance with the discharge diagnosis in 105 (86.7%; 95% CI, 80-92.7%). The concordance of US findings with the discharge diagnosis was significantly higher than that of the initial clinical impression statistically. In the initial evaluation of the patients with acute abdominal pain, US is considerably helpful in making the correct diagnosis, and that the concordance with the discharge diagnosis is high. When whole abdominal scanning is not performed, targeted US study according to the initial clinical impression decreases the clinical benefit of US.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.isversionof10.1007/s11739-008-0157-8en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectUltrasonographyen_US
dc.subjectAcute abdomenen_US
dc.subjectMaking decisionen_US
dc.subjectEmergency departmenten_US
dc.titleThe role of ultrasonography in the diagnosis and management of non-traumatic acute abdominal painen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume3en_US
dc.identifier.issue4en_US
dc.identifier.startpage349en_US
dc.identifier.endpage354en_US
dc.relation.journalInternal and Emergency Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster