dc.description.abstractObjective: To evaluate the effect of a self-etching primer on shear bond strengths (SBS) at the different debond times of 5, 15, 30, and 60 minutes and 24 hours. Materials and Methods: Brackets were bonded to human premolars with different etching protocols. In the control group (conventional method [CM]) teeth were etched with 37% phosphoric acid. In the study group, a self-etching primer (SEP; Transbond Plus Self Etching Primer; 3M Unitek, Monrovia, Calif) was applied as recommended by the manufacturer. Brackets were bonded with light-cure adhesive paste (Transbond XT; 3M Unitek) and light-cured for 20 seconds in both groups. The shear bond test was performed at the different debond times of 5, 15, 30 and 60 minutes and 24 hours. Results: Lowest SBS was attained with a debond time of 5 minutes for the CM group (9.51 MPa) and the SEP group (8.97 MPa). Highest SBS was obtained with a debond time of 24 hours for the CM group (16.82 MPa) and the SEP group (19.11 MPa). Statistically significant differences between the two groups were not observed for debond times of 5, 15, 30, or 60 minutes. However, the SBS values obtained at 24 hours were significantly different (P <.001). Conclusions: Adequate SBS was obtained with self-etching primer during the first 60 minutes (5, 15, 30 and 60 minutes) when compared with the conventional method. It is reliable to load the bracket 5 minutes after bonding using self-etching primer (Transbond Plus) with the light-cure adhesive (Transbond XT).en_US
dc.language.isoengen_US
dc.publisherE H Angle Education Research Foundation, Incen_US
dc.relation.isversionof10.2319/011606-22R.1en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectself-etching primeren_US
dc.subjectdebond timeen_US
dc.subjectbond strengthen_US
dc.titleEffects of self-etching primer on shear bond strength of orthodontic brackets at different debond timesen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume77en_US
dc.identifier.issue1en_US
dc.identifier.startpage108en_US
dc.identifier.endpage112en_US
dc.relation.journalAngle Orthodontisten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record