Basit öğe kaydını göster

dc.contributor.authorOrak, Ibrahim
dc.contributor.authorGuneren, Ethem
dc.contributor.authorYildiz, Levent
dc.date.accessioned2020-06-21T15:28:35Z
dc.date.available2020-06-21T15:28:35Z
dc.date.issued2006
dc.identifier.issn0148-7043
dc.identifier.issn1536-3708
dc.identifier.urihttps://doi.org/10.1097/01.sap.0000204035.77692.a1
dc.identifier.urihttps://hdl.handle.net/20.500.12712/20540
dc.descriptionGuneren, Ethem/0000-0002-5981-7010en_US
dc.descriptionWOS: 000238725700017en_US
dc.descriptionPubMed: 16799315en_US
dc.description.abstractThe effects of interrupted simple versus horizontal mattress sutures and of the internal diameter of the arterial pedicle at the level of the anastomosis on rat epigastric flap perfusion were investigated. In the first group, a microclip was applied to the femoral artery for 30 minutes. In the second group, the artery was cut, and a classic 7- to 8-suture microarterial end-to-end anastomosis was performed. In the third group, the artery was cut, and a microarterial end-to-end anastomosis with 3 horizontal mattress sutures at 120-degree intervals was performed. Perfusion was measured using a laser Doppler flowmeter (Periflux 2B, Perimed, Sweden) at 3 zones of the flap at 30 and 60 minutes and at 21 days after the procedure. Internal vascular diameters were measured histopathologically. Perfusion was better in the control group than in the experimental groups. However, the internal vascular diameters were greater with the classic method than with the new method, and the perfusion did not differ statistically in the anastomosis groups. In conclusion, even when significant narrowing develops at the anastomosis, flap viability is not affected.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.isversionof10.1097/01.sap.0000204035.77692.a1en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectmicrosurgeryen_US
dc.subjectmicrovascular surgeryen_US
dc.subjectvessel anastomosisen_US
dc.subjectvascular anastomosis methoden_US
dc.subjectinternal vascular diameteren_US
dc.subjectperfusionen_US
dc.subjectrat epigastric flapen_US
dc.subjectlaser Doppler flowmeteren_US
dc.titleA hemodynamic study of the effects of arterial anastomoses with interrupted simple versus horizontal mattress sutures on rat epigastric flap perfusionen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume57en_US
dc.identifier.issue1en_US
dc.identifier.startpage84en_US
dc.identifier.endpage88en_US
dc.relation.journalAnnals of Plastic Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster