Show simple item record

dc.contributor.authorDemir, A
dc.contributor.authorAcar, M
dc.contributor.authorYildiz, L
dc.contributor.authorKaracalar, A
dc.date.accessioned2020-06-21T15:29:13Z
dc.date.available2020-06-21T15:29:13Z
dc.date.issued2006
dc.identifier.issn0148-7043
dc.identifier.urihttps://doi.org/10.1097/01.sap.0000196561.92828.d7
dc.identifier.urihttps://hdl.handle.net/20.500.12712/20730
dc.descriptionDemir, Ahmet/0000-0002-8820-3122en_US
dc.descriptionWOS: 000235103300016en_US
dc.descriptionPubMed: 16432329en_US
dc.description.abstractPerforator flaps increasingly find acceptance and use in the field of reconstructive surgery due to their decreased donor-site morbidity and increased like-tissue coverage. Nevertheless, they are more prone to vascular compromise, especially when the meticulous technique they require is not employed. Pedicle twisting is a condition occasionally encountered in flap procedures, sometimes inadvertently, sometimes inevitably. In this study, circulatory comprise induced by twisting of the pedicle on a true perforator flap in a rat model is investigated. Thirty-eight Wistar-Albino rats were randomized into 4 groups, and cranial epigastric artery true perforator flaps were elevated on a single perforator. The flaps were returned as they were in the control group (it 9), and with 90 degrees, 180 degrees, and 270 degrees of torsion in groups 2 (n = 9) 3 (n = 10), and 4 (n = 10), respectively. The flaps were evaluated by their flap survival area, weight, and histopathological appearance by the end of the first week. The mean flap Survival ratios for groups 1, 2, 3, and 4 were 97.78 +/- 4.41%, 72.22 +/- 44.10% 73.50 +/- 30.46%, and 30 +/- 30.18% (mean +/- SD), respectively. The degree of degenerative changes in group 4 was found to be statistically significant (P < 0.016). Our histopathological examinations indicate that vascular compromise was moderate in group 3 and severe in group 4. Our findings suggest that under normal conditions, the pedicle of a true perforator flap must not be twisted more than 180 degrees.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.isversionof10.1097/01.sap.0000196561.92828.d7en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjecttrue perforator flapen_US
dc.subjectpedicle twistingen_US
dc.titleThe effect of twisting on perforator flap viability - An experimental study in ratsen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume56en_US
dc.identifier.issue2en_US
dc.identifier.startpage186en_US
dc.identifier.endpage189en_US
dc.relation.journalAnnals of Plastic Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record