Basit öğe kaydını göster

dc.contributor.authorSarac, YS
dc.contributor.authorSarac, D
dc.contributor.authorKulunk, T
dc.contributor.authorKulunk, S
dc.date.accessioned2020-06-21T15:30:46Z
dc.date.available2020-06-21T15:30:46Z
dc.date.issued2005
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2005.05.024
dc.identifier.urihttps://hdl.handle.net/20.500.12712/20964
dc.descriptionWOS: 000231742700008en_US
dc.descriptionPubMed: 16126078en_US
dc.description.abstractStatement of problem. Fracture of a repaired denture base often occurs at the junction of the base and repair materials rather than within these materials. Purpose. The purpose Of the Study was to evaluate the shear bond strengths of 4 denture base acrylic resins following the use of 3 chemical solvents and to examine treated acrylic resin surfaces under a field emission scanning electron microscope (SEM). Material and methods. Forty discs (15 mm in diameter and 3 mm thick) were fabricated for each denture base material (a conventionally molded, heat-polymerized [Meliodent, M], an injection-molded, heat-polymerized [SR-Ivocap, I], and a microwave-polymerized [Acron MC, A]) repaired with an aUtopolymcrizing acrylic resin (Meliodent), for a total of 120 specimens, processed according to manufacturers' instructions, embedded in acrylic resin blocks, and divided into 4 groups Of 10. One of the groups served as control and had no surface treatment. In the 3 experimental groups, specimen surfaces were treated With chemical etchants by immersion in acetone (ac) for 30 seconds, in methylene chloride (mc) for 30 seconds, or in MMA (mo) for 180 seconds, respectively. Then autopolymerizing acrylic resin (Meliodent) was placed on the treated Surfaces using a brass ring (6 mm in diameter and 2 mm in height) to confine the material to a standardized dimension. After 24 hours of storage at 37 degrees C, the shear bond strength (MPa) of the specimens was measured in a universal testing machine. A 2-way analysis of variance and the Tukey HSD test were performed to identify significant differences (alpha = .05). The nature of the failure was noted as adhesive, cohesive, or mixed. The effect of the chemical treatments on the Surface of base resins was examined under an SEM. Results. Chemical treatments increased the bond strength of repair material significantly. Significant ditrerenccs were found between the control and experimental groups (P < .001). In the control group, M showed the highest (16.7 MPa) bond strength, and A showed the lowest (9.4 MPa). No significant differences were detected between M (18.9 MPa) and A (19.9 MPa) with acetone treatment, or between M (19.3 MPa) and A (20.3 MPa) with methylenc chloride treatment. The SEM obscnations showed that application of chemical etchants produced smoother Surfaces than controls. Conclusion. Oictnical treatment prior to denture base repair showed significant improvement on the bond strength ofthe base materials. Although the microwave-polymerized acrylic resin,A, showed the lowest shear bond strength compared to the control groups, the highest pc-rcentagc increase was obtained with A after chemical treatments.en_US
dc.language.isoengen_US
dc.publisherMosby-Elsevieren_US
dc.relation.isversionof10.1016/j.prosdent.2005.05.024en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleThe effect of chemical surface treatments of different denture base resins on the shear bond strength of denture repairen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume94en_US
dc.identifier.issue3en_US
dc.identifier.startpage259en_US
dc.identifier.endpage266en_US
dc.relation.journalJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster