• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Does surgical technique influence cataract surgery contamination?

Tarih

2001

Yazar

Koc, F
Akcam, Z
Kuruoglu, S
Oge, I
Gunaydin, M

Üst veri

Tüm öğe kaydını göster

Özet

PURPOSE. To compare cataract surgery contamination rates in large-incision extracapsular cataract extraction (ECCE) and phacoemulsification (PE), we studied 65 cases prospectively. METHODS. Thirty-five cases were operated by large-incision ECCE (Group I) and 30 by PE (Group II). Conjunctival swab cultures were taken immediately before surgery and anterior chamber aspirate was taken for culture upon completion of surgery for each case. RESULTS. Anterior chamber cultures were positive in 22.8% of the cases in group I and 23% in Group II. Frequencies of contamination in each group were no different (x(2): 0.22, p>0.05). When the contaminations were evaluated in relation to operating time, prolongation of the operating time raised the contamination rate in Group I (p<0.05) but not in Group II (p>0.05). Silicone and PMMA intraocular lenses (IOL) were tested to see whether they had any additional risk of contamination. The frequencies of contaminated silicone IOL implanted cases (6/26) and contaminated PMMA IOL implanted cases (8/39) were similar (x(2): 0.36, p >0.05). CONCLUSIONS. Although the architecture of the incision and irrigation dynamics provided an advantage to the PE technique as the operating time became longer, routine PE was not superior to classical ECCE with respect to contamination when performed in the same circumstances. Prolonging the operating time raised the contamination rate in classical ECCE.

Kaynak

European Journal of Ophthalmology

Cilt

11

Sayı

1

Bağlantı

https://hdl.handle.net/20.500.12712/22238

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.