dc.description.abstract | Purpose: The reliability of poly-p-dioxanone (PDS) suture for sternal closure was tested on 264 consecutive sternotomies in the authors' department from April 1987 to May 1998. Methods: The reason for sternotomy was tetralogy of Fallot in 65 cases (24.6%), ventricular septal defect (VSD) in 38 cases (14.4%), atrial septal defect (ASD) in 77 cases (29.2%), ASD + VSD in 23 (8.7%), mitral valve replacement in 22 cases (8.3%), aortic valve replacement in 10 cases (3.8%), and other cardiac disorders in 29 cases (11.0%). Results: Sternal wound infection, sternal dehiscence, and mediastinitis occurred in 1.5% of patients (4 of 264). The overall hospital mortality rate related to the mediastinitis was 1.1% (3 of 264) in the early postoperative period. Conclusion: This absorbable suture and our different technique are a safe alternative to standard sternotomy closure after pediatric open cardiac surgery. J Pediatr Surg 35:1309-1311. Copyright (C) 2000 by W.B. Saunders Company. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | W B Saunders Co | en_US |
dc.relation.isversionof | 10.1053/jpsu.2000.9311 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | sternal closure | en_US |
dc.subject | absorbable suture | en_US |
dc.subject | poly-p-dioxanone | en_US |
dc.title | Sternal closure with resorbable synthetic loop suture material in children | en_US |
dc.type | article | en_US |
dc.contributor.department | OMÜ | en_US |
dc.identifier.volume | 35 | en_US |
dc.identifier.issue | 9 | en_US |
dc.identifier.startpage | 1309 | en_US |
dc.identifier.endpage | 1311 | en_US |
dc.relation.journal | Journal of Pediatric Surgery | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |