dc.description.abstractBackground: Frame mounting is considered one of the most critical steps in stereotactic neurosurgery. In routine clinical practice, the aim is to mount the frame as symmetrical as possible, parallel to Reid's line. However, sometimes, the frame is mounted asymmetrically often due to patient-related reasons. Methods: In this study, we addressed the question whether an asymmetrically mounted frame influences the accuracy of stereotactic electrode implantation. A Citrullus lanatus was used for this study. After a magnetic resonance imaging scan, symmetric and asymmetric mounting of the frame, which could occur in clinical scenarios, was performed with computed tomography (CT). Three different stereotactic software packages were used to analyze the results. In addition, manual calculations were performed by two different observers. Results: Our results show that an asymmetrically mounted frame (deviated, tilted, or rotated) does not affect the accuracy in the mediolateral axis (X-coordinate) or the anteroposterior axis (Y-coordinate). However, it can lead to a clinically relevant error in the superoinferior axis (Z-coordinate). This error was largest with manual calculations. Conclusion: These results suggest that asymmetrical frame mounting can lead to stereotactic inaccuracy in the superoinferior axis (Z coordinate). © 2019 Published by Scientific Scholar on behalf of Surgical Neurology Internationalen_US
dc.language.isoengen_US
dc.publisherScientific Scholaren_US
dc.relation.isversionof10.25259/SNI-88-2019en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAccuracyen_US
dc.subjectDeep brain stimulationen_US
dc.subjectFrameen_US
dc.subjectMountingen_US
dc.subjectPhantomen_US
dc.titleStereotactic accuracy and frame mounting: A phantom studyen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume10en_US
dc.identifier.issue67en_US
dc.identifier.startpage1en_US
dc.identifier.endpage7en_US
dc.relation.journalSurgical Neurology Internationalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record