dc.description.abstractTumor imaging with myocardial perfusion agents has been a focal point for researchers. A kinetic study with (99m)Technetium- methoxyisobutylisonitrile ((99m)Tc-MIBI) was performed to evaluate the tumor uptake of this radiopharmaceutical in lung cancer. Thirty-five patients with lung cancer were studied. In 21 (60%) patients, there were regions of high uptake of (99m)Tc-MIBI in the lesions. Heart/tumor, (H/T), heart/lung (H/L) and tumor/lung (T/L) ratios were obtained. H/T and H/L ratios were 1.66±0.22 and 2.10±0.28 in 2-3 min, and 1.69±0.25 and 2.14±0.27 in 29-30 min respectively. The T/L ratio was 1.28±0.10 in 2-3 min and 1.29±0.14 in 29- 30 min. While the differences between H/T and H/L ratios were statistically significant, there were no significant differences between early and late uptake ratios. Seventy per cent (7/10) of small cell and 56% (14/25) of squamous cell cancers were detected visually. (99m)Tc-MIBI uptake in small cell tumors was higher than in squamous cell tumors. Tumor blood flow was seen in the systemic phase of the radiopharmaceutical as the blood supply of the tumor was the bronchial artery. The sensitivity of (99m)Tc-MIBI planar scintigraphy for lung cancer detection was inadequate, and the early and delayed ratios revealed that small cell cancer showed higher (99m)Tc-MIBI accumulation than squamous cell cancer.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectLung canceren_US
dc.subjectPlanar scintigraphyen_US
dc.subjectTechnetium -99 m methoxyisobutylisonitrileen_US
dc.titleRadioisotopic evaluation of malignant lung tumors: A Technetium-99m- methoxy-isobutylisonitrile studyen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume29en_US
dc.identifier.issue2en_US
dc.identifier.startpage135en_US
dc.identifier.endpage140en_US
dc.relation.journalTurkish Journal of Medical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record