• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparing the intubation effectiveness of two different laryngoscopes in patients with cerebral palsy

Tarih

2018

Yazar

Çağlar Torun A.
Sari M.E.
Köksal E.
Ibiş S.

Üst veri

Tüm öğe kaydını göster

Özet

Objective: In patients with expected airway difficulties, specific preparatory and auxiliary equipment is required before general anesthesia. The aim of this study was to compare the intubation efficacy of Macintosh laryngoscope with that of the McGrath MAC video laryngoscope in patients with cerebral palsy. Materials and Methods: The study was conducted in forty patients (aged 4-15) with cerebral palsy who were scheduled to undergo dental treatment. Intubations were performed in patients randomly assigned to the McGrath MAC video laryngoscope or the Macintosh laryngoscope. The characteristics of the patients mean arterial blood pressure, heart rate, end-tidal carbon dioxide, and peripheral oxygen saturation were measured. The intubation success, intubation time, Cormack and Lehane grades, number of trials, need for neck extension, and complications were recorded. An independent sample t-test and a Mann-Whitney U test were used. A chi-square test was used for the analysis of categorical data. The level of statistical significance was accepted as p < 0.05. Results: When both groups were compared in terms of the glottic view, intubation time, and need for neck extension, there was no significant difference (p = 0.542, p = 0.779, and p = 1.000, respectively). All the intubations were performed successfully at the first attempt in both groups, and no complications were recorded. Conclusion: Although our study included patients with cerebral palsy, in which musculoskeletal anomalies are common, sufficient muscle relaxation for intubation after general anesthesia was achieved in all the patients. There was no evidence of intubation difficulty in either group of patients, and cerebral palsy, with its existing deformities, did not affect the intubation success or complication rate. No additional advantages of using video laryngoscopy in patients with cerebral palsy were found. © 2018 Cumhuriyet University Faculty of Dentistry.

Kaynak

Cumhuriyet Dental Journal

Cilt

21

Sayı

2

Bağlantı

https://doi.org/10.7126/cumudj.397203
https://hdl.handle.net/20.500.12712/5417

Koleksiyonlar

  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [4706]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.