Show simple item record

dc.contributor.authorYücel, Ali Çığın
dc.contributor.authorDemiryürek, Ebru Özsezer
dc.contributor.authorAydın, Uğur
dc.contributor.authorÖzsevik, Semih
dc.date.accessioned2020-06-21T10:14:23Z
dc.date.available2020-06-21T10:14:23Z
dc.date.issued2007
dc.identifier.issn1302-4817
dc.identifier.urihttps://app.trdizin.gov.tr/publication/paper/detail/TnpJNE5qZzQ=
dc.identifier.urihttps://hdl.handle.net/20.500.12712/7034
dc.description.abstractAmaç: Bu çalışmanın amacı değişik konsantrasyonlardaki sodyum hipoklorit solüsyonlarının Root ZX ve Apex Pointer ile yapılan kök kanal boyu ölçümleri üzerine etkisinin incelenmesidir. Gereç ve Yöntem: Çalışmamızda 15 adet üst santral kesici diş kullanılmıştır. Kök kanal boylan konvansiyonel yöntemle rad-yografik olarak hesaplanmıştır. Elektronik kök kanal boyu ölçümü için dişler aljinat içine yerleştirilmiş ve Root ZX içeren TriAuto ZX ve Apex Pointer ile ölçümleri yapılmıştır. Kanallar %1, %2.65 ve %5.25 lik konsantrasyonlarda sodyum hipoklorit ile irrige edildikten sonra iki farklı cihazla kök kanal boyları hesaplanmıştır. İstatistiksel değerlendirme tekrarlayan ölçümlerde tek faktörlü faktöriyel deneme planı (One-way ANO-VA) ile yapılmıştır. Bulgular: Tek faktörlü faktöriyel deneme planı sonuçlarına göre tüm gruplardaki örneklerin kök kanal boyları arasında istatistiksel olarak anlamlı bir fark tespit edilmemiştir. Üç farklı konsantrasyondaki NaOCl solüsyonunun iki farklı apeks bulucu ile yapılan kök kanal boyu ölçümlerinde istatistiksel olarak anlamlı bir farklılık bulunmamıştır. Sonuçlar: NaOCl' nin farklı konsantrasyonları kök kanal boyu ölçümlerinde etkili bulunmamıştır. Root ZX ve Apex Pointer ile yapılan kök kanal boyu ölçümleri radyografik yöntemle benzer sonuçlar göstermiştir.en_US
dc.description.abstractAim: The aim of this study was to evaluate of effect of different sodium hypochlorite concentration on electronic root canal length measurements. Materials and Methods: 15 maxillary central incisor teeth were used in this study. Root canal length was measured radio graphically with conventional techniques. Teeth were embedded in alginate for electronic root canal measurements and root canal lengths were measured with TriAuto ZX including Root ZX and Apex Pointer. After irrigation of canals with 1%, 2.65%, and 5.25% NaOCl, electronic root canal lengths were calculated. The data were analyzed with a repeated measures one-way ANOVA. Results: According to the results of One-Way ANOVA, there were no statistically significant differences among study groups. No significant differences were found among root canal measurements using two different apex locator with three different NaOCl solutions. Conclusion: Different concentrations of NaOCl did not affect the root canal length measurements. Root canal length measurements with Root ZX and Apex Pointer show similar results with radio graphic technique.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliğien_US
dc.titleFarklı konsantrasyonlardaki sodyum hipokloritin elektronik kök kanal boyu ölçümüne etkisien_US
dc.title.alternativeEffect of different sodium hypocholorite concentrations on electronic root canal length measurementsen_US
dc.typeotheren_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume8en_US
dc.identifier.issue2en_US
dc.identifier.startpage91en_US
dc.identifier.endpage95en_US
dc.relation.journalOndokuz Mayıs Üniv. Diş Hekimliği Derg.en_US
dc.relation.publicationcategoryDiğeren_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record