• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of anterior chamber depth measurements by the galilei dual-scheimpflug analyzer and conventional a-scan ultrasound

Tarih

2012

Yazar

Yeter, Volkan
Arıtürk, Nurşen

Üst veri

Tüm öğe kaydını göster

Özet

Amaç: Galilei Dual-Scheimpflug Analyzer (GSA) ve konvansiyonel A-Tarayıcı ultrason ile sağlıklı bireylerde elde edilen ön kamara derinlik ölçümlerinin karşılaştırılması. Gereç ve Yöntem: Bu prospektif çalışmada, 43 sağlıklı bireyin 80 gözü (30u yetişkin ve 13ü çocuk; 21i kız ve 22si erkek; ortalama yaş: 27.8615.32 yıl ) sırasıyla GSA (Ziemer Group, İsviçre) ve ultrason ile ön kamara derinliği için ölçüldü. Ölçümler arasındaki uyumluluk için; veriler Paired-T test, Bland-Altman plot, and Pearson korelasyon testi ile incelendi. Bulgular: GSA ve ultrason ile elde edilen ön kamara derinliği sırasıyla 3.580.29 mm and 3.470.33 mm idi. Ultrason ve GSA ile elde edilen ön kamara derinlik ölçümleri arasındaki fark (Ultrason eksi GSA) 0.110.14 mm iken; bu fark istatistiksel olarak anlamlıydı (p0.001). GSA ve ultrason ile elde edilen ön kamara derinlik ölçümleri arasında yüksek korelasyon mevcuttu(r0.90; p0.001). Sonuç: GSA ve ultrason ile elde edilen ön kamara derinlik ölçümleri birbirleriyle yüksek düzeyde koreledir. GSA ön kamara derinliğini, konvansiyonel ultrasondan ortalama 0.11 mm daha uzun ölçmektedir ve bu fark klinik olarak anlamsız sayılabilir.
 
Purpose: To compare the anterior chamber depth measurements (ACD) obtained by the Galilei Dual-Scheimpflug Analyzer (GSA) and conventional A-scan ultrasound in healthy subjects. Materials and Methods: In this prospective study, ACD measurements of 80 eyes of 43 healthy subjects (30 adults and 13 children; 21 females and 22 males; mean age: 27.86±15.32 years) were respectively measured by GSA (Ziemer Group, Switzerland) and ultrasound. The data was analyzed statistically by the Paired-T test, Bland-Altman plot, and Pearson correlation test to assess the agreement of the measurements. Results: The mean ACD values obtained by GSA and ultrasound were 3.58±0.29 mm and 3.47±0.33 mm, respectively. The mean difference between the ACD measurements obtained by ultrasound and GSA (GSA minus Ultrasound) was 0.11±0.14 mm and the difference between the ACD measurements of these devices was statistically significant (p<0.001). There was high correlation between the ACD measurements of GSA and those of ultrasound (r0.90; p<0.001). Conclusions: The ACD measurements of GSA and conventional A-scan ultrasound are highly correlated. GSA measures the ACD on average 0.11 mm longer than conventional ultrasound and this difference may be regarded as clinically insignificant.
 

Kaynak

Glokom Katarakt

Cilt

7

Sayı

4

Bağlantı

https://app.trdizin.gov.tr/publication/paper/detail/TVRRME5qazRPQT09
https://hdl.handle.net/20.500.12712/7971

Koleksiyonlar

  • TR-Dizin İndeksli Yayınlar Koleksiyonu [4706]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.