Effect of Dynamic Immersion in Sodium Hypochlorite and EDTA Solutions on Cyclic Fatigue Resistance of WaveOne and WaveOne Gold Reciprocating Nickel-titanium Files

Tarih

2018

Yazar

Uslu, Gulsah
Ozyurek, Taha
Yilmaz, Koray
Plotino, Gianluca

Üst veri

Tüm öğe kaydını göster

Özet

Introduction: The purpose of this study was to evaluate the effect of sodium hypochlorite (NaOCl) and EDTA solutions on the cyclic fatigue resistance of WaveOne (WO) and WaveOne Gold (WOG) nickel-titanium reciprocating files. Methods: A hundred WO (25/.08), and 100 WOG (25/.07) were randomly divided into 5 groups: group 1, no immersion; group 2, immersion in 5.25% NaOCI at 37 degrees C +/- 1 degrees C for 5 minutes; group 3, immersion in 5.25% NaOCI at 37 degrees C +/- 1 degrees C for 10 minutes; group 4, immersion in 17% EDTA at 37 degrees C +/- 1 degrees C for 5 minutes; and group 5, immersion in 17 % EDTA at 37 degrees C +/- 1 degrees C for 10 minutes. Then, the instruments were reciprocated in an artificial canal until fracture occurred, and the time to fracture was recorded. The data were statistically analyzed using 1-way analysis of variance and the Student t test via SPSS 21.0 software (IBM Corp, Armonk, NY) with the significance level set at P < .05. Results: The cyclic fatigue resistance of the WOG was statistically higher than the WO in all the conditions tested (P < .05). There was no statistically significant difference among the different conditions tested in terms of cyclic fatigue resistance for both WO and WOG files (P > .05). Among the groups, there was no significant difference in the fracture lengths (P > .05). Conclusions: Within the limitations of the present study, it was determined that NaOCl and EDTA solutions did not have any effect on the cyclic fatigue resistance of WO and WOG files.

Kaynak

Journal of Endodontics

Cilt

44

Sayı

5

Bağlantı

https://doi.org/10.1016/j.joen.2017.11.014
https://hdl.handle.net/20.500.12712/11653

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.