Clinical effectiveness of 2 orthodontic retainer wires on mandibular arch retention

Date

2018

Author

Gunay, Firdevs
Oz, Abdullah Alper

Metadata

Show full item record

Abstract

Introduction: The aim of this study was to evaluate and compare the clinical success of 2 lingual retainer wires. Methods: The 120 patients included in the study were divided into 2 groups randomly. In group 1, 0.0175-in 6-strand stainless steel wire (Ortho Technology, Lutz, Fla) was used, the lingual retainers were fabricated on plaster models, and a silicon transfer key was used. In group 2, 0.0195-in dead-soft coaxial wire (Respond; Ormco, Orange, Calif) was used, and the lingual retainers were fabricated directly in the patient's mandibular arch without a study model. Pretreatment, posttreatment, and posttreatment 3-month, 6-month, 9-month, and 12-month 3-dimensional orthodontic models were evaluated. Failure rates, mandibular arch irregularity values, intercanine distances, and arch lengths were compared. Results: The clinical bond failure rates were 13.2% for the 0.0175-in 6-strand stainless steel wire and 18.9% for the 0.0195-in dead-soft wire. The difference in bond failures between the 2 groups was not statistically significant. There was a statistically significant increase in mandibular arch irregularity in both groups during the 12-month follow-up. However, the increase was significantly higher in the second group than in the first one. Furthermore, the intercanine distance decreased over time in the second group. Conclusions: Our findings regarding mandibular arch measurements indicate that fabrication of lingual retainers can be more safely accomplished with 0.0175-in 6-strand stainless steel wire than with 0.0195-in dead-soft coaxial wire.

Source

American Journal of Orthodontics and Dentofacial Orthopedics

Volume

153

Issue

2

URI

https://doi.org/10.1016/j.ajodo.2017.06.019
https://hdl.handle.net/20.500.12712/11762

Collections

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Ondokuz Mayıs

by OpenAIRE

Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Library || Ondokuz University || OAI-PMH ||

Ondokuz Mayıs University, Samsun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Ondokuz University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.