Assessment of Heat Generation During Implant Insertion

Tarih

2014

Yazar

Sumer, Mahmut
Keskiner, Ilker
Mercan, Ugur
Misir, Ferhat
Cankaya, Soner

Üst veri

Tüm öğe kaydını göster

Özet

Statement of problem. Many studies have investigated the heat generated during implant preparation, but data are needed to better predict heat generation during implant insertion. Purpose. The purpose of this study was to measure the heat generated during insertion of an implant at speeds of 30, 50, and 100 rpm, and with manual insertion. Material and methods. Sixty-four uniform fresh bovine femoral cortical bone specimens were used. After the cortical bone was drilled, 3 different implant insertion speeds and the manual insertion of the implant were evaluated for 2 different implant diameters. The temperature was measured with 2 Teflon-insulated, type K thermocouples. Data were analyzed by 2way ANOVA, and the Tukey honestly significant difference test (Gc=.05). Results. The highest thermal change for 4.1-mm-diameter implants was found at a speed of 100 rpm (9.81 C 2.29 C), and the lowest thermal change was 3.69 C 0.85 C at a speed of 30 rpm. A statistically significant difference was found between 100 rpm and the other 3 insertion procedures. The highest thermal change for a 4.8-mm-diameter implant was found at a speed of 100 rpm (8.79 C 1.53 C), and the lowest thermal change was 4.48 C 0.85 C at a speed of 30 rpm. No statistical difference was observed with manual, 30 rpm, and 50 rpm; however, a statistically significant difference was found between 100 rpm and the other 3 insertion procedures. Conclusions. Manual implant insertion and at speeds of 30 rpm and 50 rpm generated lower heat compared with insertion at 100 rpm. (J Prosthet Dent 20:14;112:522-525)

Kaynak

Journal of Prosthetic Dentistry

Cilt

112

Sayı

3

Bağlantı

https://doi.org/10.1016/j.prosdent.2013.12.011
https://hdl.handle.net/20.500.12712/15007

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.