Device-associated nosocomial infections in 55 intensive care units of 8 developing countries

Tarih

2006

Yazar

Rosenthal, Victor D.
Maki, Dennis G.
Salomao, Reinaldo
Alvarez-Moreno, Carlos
Mehta, Yatin
Higuera, Francisco
Leblebicioglu, Hakan

Üst veri

Tüm öğe kaydını göster

Özet

Background: Health care-associated infections from invasive medical devices in the intensive care unit (ICU) are a major threat to patient safety. Most published studies of ICU-acquired infections have come from industrialized western countries. In a Centers for Disease Control and Prevention (CDC) National Nosocomial Infections Surveillance (NNIS) System report, the U.S. pooled mean rates of central venous catheter (CVC)-related bloodstream infections, ventilator-associated pneumonia, and catheter-associated urinary tract infections were 4.0 per 1000 CVC days, 5.4 per 1000 mechanical ventilator days, and 3.9 per Foley catheter days, respectively. Objective: To ascertain the incidence of device-associated infections in the ICUs of developing countries. Design: Multicenter, prospective cohort surveillance of device-associated infection by using the CDC NNIS System definitions. Setting: 55 ICUs of 46 hospitals in Argentina, Brazil, Colombia, India, Mexico, Morocco, Peru, and Turkey that are members of the International Nosocomial Infection Control Consortium (INICC). Measurements: Rates of device-associated infection per 100 patients and per 1000 device days. Results: During 2002-2005, 21 069 patients who were hospitalized in ICUs for an aggregate 137 740 days acquired 3095 device-associated infections for an overall rate of 14.7% or 22.5 infections per 1000 ICU days. Ventilator-associated pneumonia posed the greatest risk (41% of all device-associated infections or 24.1 cases [range, 10.0 to 52.7 cases] per 1000 ventilator days), followed by CVC-related bloodstream infections (30% of all device-associated infections or 12.5 cases [range, 7.8 to 18.5 cases] per 1000 catheter days) and catheter-associated urinary tract infections (29% of all device-associated infections or 8.9 cases (range, 1.7 to 12.8 cases) per 1000 catheter days). Notably, 84% of Staphylococcus aureus infections were caused by methicillin-resistant strains, 51% of Enterobacteriaceae isolates were resistant to ceftriaxone, and 59% of Pseudomonas aeruginosa isolates were resistant to fluoro-quinolones. The crude mortality rate for patients with device-associated infections ranged from 35.2% (for CVC-associated bloodstream infection) to 44.9% (for ventilator-associated pneumonia). Limitations: These initial data are not adequate to represent any entire country, and likely variations in the efficiency of surveillance and institutional resources may have affected the rates that were detected. Conclusions: Device-associated infections in the ICUs of these developing countries pose greater threats to patient safety than in U.S. ICUs. Active infection control programs that perform surveillance of infection and implement guidelines for prevention can improve patient safety and must become a priority in every country.

Kaynak

Annals of Internal Medicine

Cilt

145

Sayı

8

Bağlantı

https://doi.org/10.7326/0003-4819-145-8-200610170-00007
https://hdl.handle.net/20.500.12712/20376

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.