The effect of curing lights and modes on dentin bond strength of bulk-fill composites applied in different thickness

Tarih

2019

Yazar

Misilli, Tugba
Gonulol, Nihan
Cabadag, Ozge Gizem
Almasifar, Lena
Misilli, Umut

Üst veri

Tüm öğe kaydını göster

Özet

To investigate shear bond strength (SBS) to dentin of a conventional and three bulk-fill composites applied in different increment thickness and cured by mono- and multi-wave LED LCUs. Two hundred and fifty-two extracted sound human molars were prepared for SBS test. The teeth were divided into four groups according to the resin composites used. Conventional composite: Tetric N-Ceram (control); high-viscosity bulk-fills: Tetric N-Ceram Bulk Fill, X-tra Fil, and SonicFill. Each group was subdivided (n = 7) according to increment thickness (2, 4, and 6 mm) and cured by standard mode of a mono-wave LED or two different modes (standard and xtra power) of a multi-wave LED. The failure mode was stereomicroscopically determined at 40x magnification. Data were analyzed using Three-way ANOVA and further comparisons were assessed by Bonferroni's multiple comparison test. There were no significant differences within X-tra fil and Tetric N-Ceram Bulk Fill groups for any of the variables (p > 0.05). A significant decrease in SBS values with increase of layer thickness was observed for SonicFill and control groups. Also, curing mode had a significant effect on both composites at 6 mm thickness and standard mode of multi-wave LED caused the highest SBS value (p < 0.05). Adhesive failure was the most common fracture pattern especially at 6 mm thickness applications. Based on the results of this study, the bulk-fill composites can be safely applied in one-step with 4 mm increments, although the examined composites performed better at 2 mm thickness. The performance of the composites at 6 mm increment may show differences related to the curing lights and modes.

Kaynak

Journal of Adhesion Science and Technology

Cilt

33

Sayı

20

Bağlantı

https://doi.org/10.1080/01694243.2019.1640174
https://hdl.handle.net/20.500.12712/10716

Koleksiyonlar

  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.