dc.description.abstractStatement of problem. Many studies have investigated the heat generated during implant preparation, but data are needed to better predict heat generation during implant insertion. Purpose. The purpose of this study was to measure the heat generated during insertion of an implant at speeds of 30, 50, and 100 rpm, and with manual insertion. Material and methods. Sixty-four uniform fresh bovine femoral cortical bone specimens were used. After the cortical bone was drilled, 3 different implant insertion speeds and the manual insertion of the implant were evaluated for 2 different implant diameters. The temperature was measured with 2 Teflon-insulated, type K thermocouples. Data were analyzed by 2way ANOVA, and the Tukey honestly significant difference test (Gc=.05). Results. The highest thermal change for 4.1-mm-diameter implants was found at a speed of 100 rpm (9.81 C 2.29 C), and the lowest thermal change was 3.69 C 0.85 C at a speed of 30 rpm. A statistically significant difference was found between 100 rpm and the other 3 insertion procedures. The highest thermal change for a 4.8-mm-diameter implant was found at a speed of 100 rpm (8.79 C 1.53 C), and the lowest thermal change was 4.48 C 0.85 C at a speed of 30 rpm. No statistical difference was observed with manual, 30 rpm, and 50 rpm; however, a statistically significant difference was found between 100 rpm and the other 3 insertion procedures. Conclusions. Manual implant insertion and at speeds of 30 rpm and 50 rpm generated lower heat compared with insertion at 100 rpm. (J Prosthet Dent 20:14;112:522-525)en_US
dc.language.isoengen_US
dc.publisherMosby-Elsevieren_US
dc.relation.isversionof10.1016/j.prosdent.2013.12.011en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleAssessment of Heat Generation During Implant Insertionen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume112en_US
dc.identifier.issue3en_US
dc.identifier.startpage522en_US
dc.identifier.endpage525en_US
dc.relation.journalJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster