Basit öğe kaydını göster

dc.contributor.authorInan, Ugur
dc.contributor.authorGonulol, Nihan
dc.date.accessioned2020-06-21T14:54:28Z
dc.date.available2020-06-21T14:54:28Z
dc.date.issued2009
dc.identifier.issn0099-2399
dc.identifier.urihttps://doi.org/10.1016/j.joen.2009.06.014
dc.identifier.urihttps://hdl.handle.net/20.500.12712/18418
dc.descriptionWOS: 000271037200015en_US
dc.descriptionPubMed: 19801238en_US
dc.description.abstractIntroduction: In recent years, a number of rotary nickel titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system. Although the NiTi instruments are more flexible than the stainless steel files, the main problem with the rotary NiTi instruments is the failure of the instruments. The aim of this study was to evaluate the deformation and fracture rate of Mtwo rotary nickel-titanium instruments (VDW, Munich, Germany) discarded after routine clinical use. Methods: A total of 593 Mtwo rotary NiTi instruments were collected after clinical use from the clinic of endodontics over 12 months. The length of the files was measured using a digital caliper to determine any fracture, and then all the files were evaluated under a stereomicroscope for defects such as unwinding, curving, or bending and fracture. The fracture faces of separated files were also evaluated under a scanning electron microscope. The data were analyzed using a chi-square and z test. Results: A percentage of all files (25.80%) showed defects, and the major defect was fracture (16.02%). The most frequently fractured file was #10.04 (30.39%). Deformations without fracture were mostly observed on #15.05 files (25.47%). Conclusions: A higher rate of deformation was observed for #10.04 and #15.05 files. Therefore, these files should be considered as single-use instruments. Because cyclic fatigue was the cause of 71.58% of the instrument fractures, it is also important not to exceed the maximum number of usage recommended by the manufacturer and discard the instruments on a regular basis. (J Endod 2009,35:1396-1399)en_US
dc.language.isoengen_US
dc.publisherElsevier Science Incen_US
dc.relation.isversionof10.1016/j.joen.2009.06.014en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectClinical useen_US
dc.subjectnickel-titaniumen_US
dc.subjectfractureen_US
dc.subjectMtwoen_US
dc.titleDeformation and Fracture of Mtwo Rotary Nickel-Titanium Instruments After Clinical Useen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume35en_US
dc.identifier.issue10en_US
dc.identifier.startpage1396en_US
dc.identifier.endpage1399en_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster