In vivo intraaneurysmal pressure measurements in experimental lateral wall aneurysms before and after onyx embolization

Tarih

2006

Yazar

Acar F.
Men S.
Tayfur V.
Yilmaz O.
Erbayraktar S.
Metin Güner E.

Üst veri

Tüm öğe kaydını göster

Özet

Background: The aim of this study is to measure and compare the in vivo intraaneurysmal pressures of experimental lateral wall aneurysms, before and after onyx embolization. The data of this experiment will carry an important role in forming the scientific basis for the clinical endovascular applications. Materials and Methods: Five experimental lateral wall aneurysms were created by microsurgical techniques in 5 New Zealand rabbits' right common carotid arteries. Onyx embolization was applied to the aneurysms. Intraaneurysmal dome pressure and parent artery measurements before and after the procedure were recorded. Results: The mean arterial pressure recording in parent artery was 69.2 ± 2.588 mm Hg under anesthesia. Mean heart rate was 131 beats per minute. The values were in physiologic limits. Meanwhile, aneurysm intradomal pressure recording showed a mean value of 59.2 ± 5.069 mm Hg. Although there was incomplete occlusion of the aneurysm, intradomal mean pressure was recorded to be 24.4 ± 8.876 mm Hg. After complete occlusion by onyx, mean intradomal aneurysm pressure was found to be 1.8 ± 0.836 mm Hg. Discussion: This study is the first study reporting on intraaneurysmal pressure measurements before and after onyx embolization. The results in this experiment tend to show the adequate intraaneurysmal pressure control of onyx. This is important in the stabilization of the aneurysm to prevent rupture and rerupture. When compared with the findings of GDC coil, onyx embolization seems to be superior in intraaneurysmal pressure control. Conclusion: In this study, it has been shown that onyx embolization decreases the intradomal aneurysmal pressure effectively. © 2006 Elsevier Inc. All rights reserved.

Kaynak

Surgical Neurology

Cilt

66

Sayı

3

Bağlantı

https://doi.org/10.1016/j.surneu.2006.03.036
https://hdl.handle.net/20.500.12712/3427

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.