Basit öğe kaydını göster

dc.contributor.authorAcar F.
dc.contributor.authorMen S.
dc.contributor.authorTayfur V.
dc.contributor.authorYilmaz O.
dc.contributor.authorErbayraktar S.
dc.contributor.authorMetin Güner E.
dc.date.accessioned2020-06-21T09:23:11Z
dc.date.available2020-06-21T09:23:11Z
dc.date.issued2006
dc.identifier.issn0090-3019
dc.identifier.urihttps://doi.org/10.1016/j.surneu.2006.03.036
dc.identifier.urihttps://hdl.handle.net/20.500.12712/3427
dc.descriptionPubMed: 16935627en_US
dc.description.abstractBackground: The aim of this study is to measure and compare the in vivo intraaneurysmal pressures of experimental lateral wall aneurysms, before and after onyx embolization. The data of this experiment will carry an important role in forming the scientific basis for the clinical endovascular applications. Materials and Methods: Five experimental lateral wall aneurysms were created by microsurgical techniques in 5 New Zealand rabbits' right common carotid arteries. Onyx embolization was applied to the aneurysms. Intraaneurysmal dome pressure and parent artery measurements before and after the procedure were recorded. Results: The mean arterial pressure recording in parent artery was 69.2 ± 2.588 mm Hg under anesthesia. Mean heart rate was 131 beats per minute. The values were in physiologic limits. Meanwhile, aneurysm intradomal pressure recording showed a mean value of 59.2 ± 5.069 mm Hg. Although there was incomplete occlusion of the aneurysm, intradomal mean pressure was recorded to be 24.4 ± 8.876 mm Hg. After complete occlusion by onyx, mean intradomal aneurysm pressure was found to be 1.8 ± 0.836 mm Hg. Discussion: This study is the first study reporting on intraaneurysmal pressure measurements before and after onyx embolization. The results in this experiment tend to show the adequate intraaneurysmal pressure control of onyx. This is important in the stabilization of the aneurysm to prevent rupture and rerupture. When compared with the findings of GDC coil, onyx embolization seems to be superior in intraaneurysmal pressure control. Conclusion: In this study, it has been shown that onyx embolization decreases the intradomal aneurysmal pressure effectively. © 2006 Elsevier Inc. All rights reserved.en_US
dc.language.isoengen_US
dc.relation.isversionof10.1016/j.surneu.2006.03.036en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAneurysmen_US
dc.subjectIn vivoen_US
dc.subjectOnyxen_US
dc.subjectPressureen_US
dc.titleIn vivo intraaneurysmal pressure measurements in experimental lateral wall aneurysms before and after onyx embolizationen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume66en_US
dc.identifier.issue3en_US
dc.identifier.startpage252en_US
dc.identifier.endpage256en_US
dc.relation.journalSurgical Neurologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster