Assessment of Heat Generation During Implant Insertion

Date

2014

Author

Sumer, Mahmut
Keskiner, Ilker
Mercan, Ugur
Misir, Ferhat
Cankaya, Soner

Metadata

Show full item record

Abstract

Statement of problem. Many studies have investigated the heat generated during implant preparation, but data are needed to better predict heat generation during implant insertion. Purpose. The purpose of this study was to measure the heat generated during insertion of an implant at speeds of 30, 50, and 100 rpm, and with manual insertion. Material and methods. Sixty-four uniform fresh bovine femoral cortical bone specimens were used. After the cortical bone was drilled, 3 different implant insertion speeds and the manual insertion of the implant were evaluated for 2 different implant diameters. The temperature was measured with 2 Teflon-insulated, type K thermocouples. Data were analyzed by 2way ANOVA, and the Tukey honestly significant difference test (Gc=.05). Results. The highest thermal change for 4.1-mm-diameter implants was found at a speed of 100 rpm (9.81 C 2.29 C), and the lowest thermal change was 3.69 C 0.85 C at a speed of 30 rpm. A statistically significant difference was found between 100 rpm and the other 3 insertion procedures. The highest thermal change for a 4.8-mm-diameter implant was found at a speed of 100 rpm (8.79 C 1.53 C), and the lowest thermal change was 4.48 C 0.85 C at a speed of 30 rpm. No statistical difference was observed with manual, 30 rpm, and 50 rpm; however, a statistically significant difference was found between 100 rpm and the other 3 insertion procedures. Conclusions. Manual implant insertion and at speeds of 30 rpm and 50 rpm generated lower heat compared with insertion at 100 rpm. (J Prosthet Dent 20:14;112:522-525)

Source

Journal of Prosthetic Dentistry

Volume

112

Issue

3

URI

https://doi.org/10.1016/j.prosdent.2013.12.011
https://hdl.handle.net/20.500.12712/15007

Collections

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Ondokuz Mayıs

by OpenAIRE

Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Library || Ondokuz University || OAI-PMH ||

Ondokuz Mayıs University, Samsun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Ondokuz University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.